🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Classificação da eficiência energética do prédio administrativo de universidade pública em Caraúbas/RN pelo método INI-C.

dc.contributor.advisorSilva, Leonete Cristina de Araújo Ferreira Medeiros
dc.contributor.advisormailleonete.cristina@ufersa.edu.br
dc.contributor.authorTorres, Lucas Edson de Lima
dc.contributor.referee1Silva, Leonete Cristina de Araújo Ferreira Medeiros
dc.contributor.referee2Pinto, Erica Natasche de Medeiros Gurgel
dc.contributor.referee3Pereira, Alison Kaio Dantas
dc.coverage.spatialCaraúbas
dc.date.accessioned2025-04-01T14:27:24Z
dc.date.available2025-04-01T14:27:24Z
dc.date.issued2025-03-21
dc.description.abstractA eficiência energética refere-se à execução de atividades de forma que o consumo de energia seja reduzido, promovendo assim conforto e qualidade. Esse aspecto é crucial para diminuir o uso de energia, atenuar os impactos ambientais e, consequentemente, reduzir os custos. Este trabalho teve como objetivo classificar, segundo os critérios da eficiência energética, o prédio administrativo de uma universidade situada no Nordeste brasileiro. A edificação do estudo foi o Prédio Administrativo Campus Caraúbas (PACC), selecionado por funcionar durante os três turnos de atividades escolares. A coleta de dados para obtenção dos resultados foi realizada por meio de levantamento, parâmetros obtidos com o emprego do Software Revit e aplicação da metodologia indicada na Portaria Nº 309 INI-C do INMETRO. Com as informações obtidas, foi possível constatar que a edificação estudada apresenta variações na densidade de carga térmica entre as áreas estudadas, com índices elevados nas zonas 2 e 4, assim como a carga térmica total anual do prédio. No qual, é possível comparar carga térmica real (CgTTreal) e a carga térmica de referência (CgTTref), sendo classificada como CLASSE E. Isso evidencia a necessidade de implementar estratégias que visem uma melhor eficiência térmica, aumentando o conforto térmico para os usuários.
dc.description.abstract2Energy efficiency refers to carrying out activities in such a way that energy consumption is reduced, thus promoting comfort and quality. This aspect is crucial to reducing energy use. Mitigate environmental impacts and, consequently, reduce costs. The aim of this study was to classify, according to energy efficiency criteria, the administrative building of a university located in northeastern Brazil. The building of the study was the Caraúbas Campus Administrative Building (PACC), selected because it operates during the three shifts of school activities. Data collection to obtain the result was carried out by means of a survey; parameters were obtained using the Revit and application of the methodology indicated in INMETRO Ordinance No. 309 INI-C. With the information obtained, it was possible to see that the building studied has variations in thermal load density between the areas studied, with high rates in zones 2 and 4.zones 2 and 4, as well as the building's total annual thermal load. In which it is possible to compare the actual thermal load (CgTTreal) and the reference thermal load (CgTTref).reference thermal load (CgTTref), being classified as CLASS E. This highlights the need to implement strategies aimed at improving thermal efficiency, increasing thermal comfort for users.
dc.description.physical30 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationTORRES, Lucas Edson de Lima. Classificação da eficiência energética do prédio administrativo de universidade pública em Caraúbas/RN pelo método INI-C. 2025. 30 f. TCC (Graduação) - Curso de Engenharia Civil, Departamento de Engenharias, Universidade Federal Rural do Semi Árido (Ufersa), Caraúbas, 2025.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/12799
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Caraúbas - CMC
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA CIVIL
dc.subject.keywordMétodo simplificado do INI-C
dc.subject.keywordCarga térmica
dc.subject.keywordSelo Procel Edifica
dc.subject.keywordConsumo de energia
dc.titleClassificação da eficiência energética do prédio administrativo de universidade pública em Caraúbas/RN pelo método INI-C.
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
LucasELT_ART.pdf
Tamanho:
1,22 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: