🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Desenvolvimento de um reator químico para testes de degradação de Fenol usando Processos Oxidativos Avançados

dc.contributor.advisorBarbosa, Andréa Francisca Fernandes
dc.contributor.advisormailandrea.barbosa@ufersa.edu.br
dc.contributor.authorAraújo, Glaíce Oliveira
dc.contributor.referee1Barbosa, Andréa Francisca Fernandes
dc.contributor.referee2Cunha, Jardel Dantas da
dc.contributor.referee3Mota, André Luis Novais
dc.coverage.spatialMossoró
dc.date.accessioned2025-07-18T13:04:45Z
dc.date.available2025-07-18T13:04:45Z
dc.date.issued2025-03-24
dc.description.abstractO aumento da demanda por derivados do petróleo tem intensificado a produção de efluentes complexos, como a água produzida do petróleo, que requer tratamento adequado para descarte em rios e mares ou reutilização na indústria, agricultura e fruticultura. Diante da ineficácia dos tratamentos convencionais na remoção de compostos orgânicos dissolvidos, como os fenóis, os Processos Oxidativos Avançados (POAs) emergem como uma alternativa promissora para complementar as Estações de Tratamento de Água Produzida (ETAPs). Este estudo avalia a aplicação dos processos FENTON, UV e FOTO-FENTON na degradação de matéria orgânica em solução, baseados na geração do radical hidroxila a partir da reação do peróxido de hidrogênio com íons ferrosos e/ou radiação UV, transformando cadeias orgânicas em compostos inorgânicos e/ou biodegradáveis, com ou sem radiação luminosa. Utilizou-se um reator em escala de bancada com lâmpadas UVC (95W ou 190W), operando com 2L de solução de fenol em tubos de borossilicato de 868,6 cm³, auxiliado por uma bomba peristáltica de 450mL/min. As amostras, coletadas em intervalos de até 60 minutos, foram analisadas quanto à absorbância e Carbono Orgânico Total (COT) no Laboratório de Traços da UFC. Os resultados, comparados com referências bibliográficas e normas regulamentadoras, demonstraram a eficácia dos POAs. O processo FENTON alcançou 50% de eficiência após uma hora, enquanto o FOTO-FENTON atingiu 80% em apenas 15 minutos, utilizando uma única lâmpada UVC de 95W. Esta diferença ressalta o impacto positivo da radiação luminosa na eficiência do tratamento, sugerindo o potencial dos POAs como solução viável para o tratamento avançado de efluentes petrolíferos.
dc.description.abstract2The increasing demand for petroleum derivatives has intensified the production of complex effluents, such as produced water from oil extraction, which requires adequate treatment for discharge into rivers and seas or reuse in industry, agriculture, and horticulture. Given the ineffectiveness of conventional treatments in removing dissolved organic compounds, such as phenols, Advanced Oxidation Processes (AOPs) emerge as a promising alternative to complement Produced Water Treatment Plants (PWTPs). This study evaluates the application of FENTON, UV, and PHOTO-FENTON processes in the degradation of organic matter in solution, based on the generation of hydroxyl radicals from the reaction of hydrogen peroxide with ferrous ions and/or UV radiation, transforming organic chains into inorganic and/or biodegradable compounds, with or without light radiation. A bench-scale reactor with UVC lamps (95W or 190W) was used, operating with 2L of phenol solution in 868.6 cm³ borosilicate tubes, aided by a 450mL/min peristaltic pump. Samples, collected at intervals of up to 60 minutes, were analyzed for absorbance and Total Organic Carbon (TOC) at the UFC Trace Laboratory. The results, compared with bibliographic references and regulatory standards, demonstrated the effectiveness of AOPs. The FENTON process achieved 50% efficiency after one hour, while PHOTO-FENTON reached 80% in just 15 minutes, using a single 95W UVC lamp. This difference highlights the positive impact of light radiation on treatment efficiency, suggesting the potential of AOPs as a viable solution for advanced treatment of petroleum effluents.
dc.description.physical85 f.
dc.description.sponsorshipPrograma de Recursos Humanos da Agência Nacional do Petróleo, Gás Natural e Biocombustíveis (PRH-ANP 55.1)
dc.format.mimetypepdf
dc.identifier.bibliographicCitationARAÚJO, Glaíce. Desenvolvimento de um reator químico para testes de degradação de Fenol usando Processos Oxidativos Avançados. 2025. 85 f. TCC (Bacharelado em Engenharia Química) - Universidade Federal Rural do Semi-Árido, Mossoró, 2025.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/13565
dc.language.isopt_BR
dc.publisher.centerCentro de Engenharias - CE
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA QUIMICA
dc.subject.keywordProcessos de oxidação avançada
dc.subject.keywordReator Fotocatalítico
dc.subject.keywordFenol
dc.subject.keywordFENTON
dc.subject.keywordUV
dc.subject.keywordPhenol
dc.subject.keywordFOTO-FENTON
dc.subject.keywordAdvanced oxidative processes plant
dc.subject.keywordPhotocatalytic reactor
dc.titleDesenvolvimento de um reator químico para testes de degradação de Fenol usando Processos Oxidativos Avançados
dc.title.alternativeDevelopment of a chemical reactor for Phenol degradation tests using Advanced Oxidative Processes
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
AraújoGO.pdf
Tamanho:
2,08 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: