Avaliação da eficiência energética de uma residência universitária no semiárido
| dc.contributor.advisor | Silva, Leonete Cristina de Araujo Ferreira Medeiros | |
| dc.contributor.advisormail | leonete.cristina@ufersa.edu.br | |
| dc.contributor.author | Fernandes, Thalia Ariadna Alves | |
| dc.contributor.referee1 | Silva, Leonete Cristina de Araujo Ferreira Medeiros | |
| dc.contributor.referee2 | Torres, Lucas Edson de Lima | |
| dc.contributor.referee3 | Pinto, Erica Natasche de Medeiros Gurgel | |
| dc.coverage.spatial | Caraúbas | |
| dc.date.accessioned | 2025-08-15T18:52:05Z | |
| dc.date.available | 2025-08-15T18:52:05Z | |
| dc.date.issued | 2025-07-31 | |
| dc.description.abstract | O projeto e a construção de edificações dotadas de eficiência energética são prerrogativas das normas técnicas brasileiras, em especial em áreas de clima semiárido, nas quais as condições ambientais trazem desafios extras ao desempenho térmico e ao conforto dos usuários. Assim, o objetivo do trabalho foi avaliar a classificação de uma residência universitária pública no semiárido potiguar, segundo o método simplificado da INI-R (Portaria Inmetro nº 309/2022), no âmbito do Programa Brasileiro de Etiquetagem de Edificações (PBE Edifica). A metodologia compreendeu as seguintes etapas: levantamento da documentação técnica do prédio, a realização de visita in loco para identificação das características construtivas e sistemas instalados, a modelagem digital no software Autodesk Revit e a aplicação dos parâmetros normativos para a classificação de eficiência energética. A edificação obteve Classe C na avaliação global. O desempenho da envoltória foi limitado por 𝑇𝑜𝑚𝑎𝑥acima do limiar tolerado para a zona bioclimática adotada e por redução insuficiente da carga térmica total face ao modelo de referência. Concluiu-se que o trabalho oferece subsídios técnicos para a implementação de ações de retrofit e para o planejamento de edificações mais eficientes no âmbito institucional, contribuindo para a redução do consumo de energia e para a promoção da sustentabilidade em universidades públicas. | |
| dc.description.abstract2 | The design and construction of energy-efficient buildings are prerogatives of Brazilian technical standards, especially in semi-arid climates, where environmental conditions pose additional challenges to thermal performance and occupant comfort. Therefore, the objective of this study was to evaluate the classification of a public university residence in the semi-arid region of Rio Grande do Norte, according to the simplified INI-R method (Inmetro Ordinance No. 309/2022), within the scope of the Brazilian Building Labeling Program (PBE Edifica). The methodology comprised the following steps: a survey of the building's technical documentation, an on-site visit to identify its construction features and installed systems, digital modeling in Autodesk Revit software, and the application of regulatory parameters for energy efficiency classification. The building received a Class C rating in the overall assessment. The envelope's performance was limited by 𝑇𝑜𝑚𝑎𝑥 above the tolerated threshold for the adopted bioclimatic zone and by insufficient reduction of the total thermal load compared to the reference model. It was concluded that the work offers technical support for the implementation of retrofit actions and for the planning of more efficient buildings within the institutional scope, contributing to the reduction of energy consumption and the promotion of sustainability in public universities. | |
| dc.description.physical | 25 f. | |
| dc.format.mimetype | ||
| dc.identifier.advisorLattes | http://lattes.cnpq.br/7743815895959862 | |
| dc.identifier.bibliographicCitation | FERNANDES, Thalia Ariadna Alves. Avaliação da eficiência energética de uma residência universitária no semiárido. 2025. 25 f. TCC (Graduação) - Curso de Engenharia Civil, Departamento de Engenharias, Universidade Federal Rural do Semiárido, Caraúbas, 2025. | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/13829 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro Multidisciplinar de Caraúbas - CMC | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | Departamento de Engenharias - DE/CMC | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.holder | UFERSA | |
| dc.rights.license | Attribution-ShareAlike 3.0 Brazil | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/3.0/br/ | |
| dc.subject.cnpq | ENGENHARIAS::ENGENHARIA CIVIL | |
| dc.subject.keyword | Desempenho térmico da envoltória | |
| dc.subject.keyword | PBE Edifica | |
| dc.subject.keyword | Etiquetagem de edificações | |
| dc.subject.keyword | Semiárido | |
| dc.subject.keyword | Edificações universitárias. | |
| dc.subject.keyword | Thermal performance of the envelope | |
| dc.subject.keyword | Building labeling | |
| dc.subject.keyword | University buildings. | |
| dc.title | Avaliação da eficiência energética de uma residência universitária no semiárido | |
| dc.title.alternative | Energy efficiency assessment of a university residence in the semi-arid region | |
| dc.type | info:eu-repo/semantics/bachelorThesis |