🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Desenvolvimento e aplicação de dispositivo microfluídico tratado com plasma atmosférico frio na seleção de espermatozoides epididimários de carneiros

dc.contributor.advisorBezerra, Marcelo Barbosa
dc.contributor.advisormailmbezerra@ufersa.edu.br
dc.contributor.authorFernandes, Beatriz Dantas
dc.contributor.referee1Bezerra, Marcelo Barbosa
dc.contributor.referee2Silva, Alexandre Rodrigues
dc.contributor.referee3Moura, Carlos Eduardo Bezerra de
dc.contributor.referee4Borges, Cibele dos Santos
dc.contributor.referee5Ferreira, Maricy Apparício
dc.coverage.spatialMossoró
dc.date.accessioned2025-05-19T21:13:23Z
dc.date.available2025-05-19T21:13:23Z
dc.date.issued2024-04-26
dc.description.abstractA seleção de espermatozoides viáveis é uma etapa crucial durante a produção in vitro de embriões, entretanto, os atuais métodos para isso envolvem centrifugação e podem ser prejudiciais às células. Por essa razão, estão sendo estudados dispositivos microfluídicos que permitem a seleção dos espermatozoides sem interferências externas. O polidimetilsiloxano (PDMS) é o material mais utilizado na confecção de dispositivos microfluídicos, porém é extremamente hidrofóbico, dificultado o preenchimento de canais do dispositivo. Até o momento não há estudos com seleção espermática em carneiros, assim como não há estudos avaliando a influência da aplicação do plasma atmosférico nos dispositivos microfluídicos. Dessa forma, o objetivo deste estudo foi definir parâmetros para aplicação do plasma atmosférico para modificação de superfície de PDMS e avaliar a eficiência de um dispositivo microfluídico na seleção de espermatozoides de carneiros a partir da quimiotaxia. Para o primeiro experimento, foram fabricados discos de PDMS que receberam o tratamento com plasma e foram avaliados após 0h, 3h, 6h, 9h e 24h para molhabilidade. Após isso, foram fabricados dispositivos microfluícidos com PDMS para o segundo experimento, que possuíam um reservatório de entrada interligado a três reservatórios de saída. O grupo controle consistiu em dispositivos não tratados, enquanto o grupo tratamento correspondia aos dispositivos tratados com plasma durante 15 minutos. Imediatamente após a aplicação, os dispositivos eram preenchidos com três meios diferentes nos reservatórios de saída, sendo eles: meio de FIV, solução NaCl 0,9%, e meio de MIV. Após isso, o reservatório de entrada foi preenchido com amostra de espermatozoides epididimários de carneiro. O dispositivo foi incubado por 35 minutos e, posteriormente, as amostras foram coletadas para avaliar os parâmetros de motilidade através do CASA, morfologia com uso de rosa bengala, e viabilidade e integridade, através de microscopia de fluorescência e teste hisposmótico, respectivamente. Os dados foram expressos em valores de média ± desvio padrão. Primeiramente, os dados foram examinados quanto à normalidade usando o teste de Shapiro-Wilk e para a homocedasticidade usando teste de Levene. Diferenças foram consideradas significativas quando p < 0,05. Em relação à molhabilidade, foi possível verificar que a aplicação do plasma atmosférico alterou a superfície de PDMS para altamente hidrofílica até 3 horas (27,31º ± 5,61º) após a aplicação do plasma (p < 0,05). Com o passar do tempo verificou-se que o ângulo de contato apresentou aumento gradual, porém ainda inferior ao avaliado antes do tratamento (86,31º ± 8,16º). Já em relação à seleção espermática, observou-se que o meio FIV do grupo tratamento apresentou parâmetros superiores para motilidade total (58,4 ± 16,9) e motilidade progressiva (43,9 ± 18,9) em relação aos demais meios testados (p < 0,05) e sendo semelhante com as amostras selecionadas pelo gradiente de Percoll em todos os parâmetros. Além disso, a aplicação do plasma atmosférico não influenciou na seleção de espermatozoides, ou seja, o uso ou não do plasma atmosférico não causa melhorias ou facilidade na seleção. Dessa forma, a confecção de um novo dispositivo microfluídico foi eficiente na seleção de espermatozoides de carneiros quando comparado ao gradiente de Percoll.
dc.description.abstract2The selection of viable sperm is a crucial step during the in vitro production of embryos, however, current methods for this involve centrifugation and can be harmful to cells. For this reason, microfluidic devices that allow sperm selection without external interference are being studied. Polydimethylsiloxane (PDMS) is the most widely used material in the manufacture of microfluidic devices, but it is extremely hydrophobic, making it difficult to fill the device's channels. To date, there are no studies with sperm selection in sheep, as well as no studies evaluating the influence of the application of atmospheric plasma on microfluidic devices. Thus, the objective of this study was to define parameters for the application of atmospheric plasma for PDMS surface modification and to evaluate the efficiency of a microfluidic device in the selection of sheep spermatozoa from chemotaxis. For the first experiment, PDMS discs were manufactured and treated with plasma and evaluated after 0h, 3h, 6h, 9h and 24h for wettability. After that, microfluidic devices with PDMS were manufactured for the second experiment, which had an inlet reservoir interconnected to three outlet reservoirs. The control group consisted of untreated devices, while the treatment group corresponded to the plasma-treated devices for 15 minutes. Immediately after application, the devices were filled with three different media in the outlet reservoirs, namely: IVF medium, 0.9% NaCl solution, and IVM medium. After that, the inlet reservoir was filled with sheep epididymal sperm samples. The device was incubated for 35 minutes and, subsequently, samples were collected to evaluate motility parameters through CASA, morphology with the use of rose cane, and viability and integrity, through fluorescence microscopy and hisposmotic test, respectively. Data were expressed as mean ± standard deviation values. First, the data were examined for normality using the Shapiro-Wilk test and for homoscedasticity using the Levene test. Differences were considered significant when p < 0.05. Regarding the wettability, it was possible to verify that the application of atmospheric plasma changed the PDMS surface to highly hydrophilic up to 3 hours (27.31º ± 5.61º) after plasma application (p < 0.05). Over time, it was found that the contact angle showed a gradual increase, but still lower than that evaluated before the treatment (86.31º ± 8.16º). Regarding sperm selection, it was observed that the IVF medium of the treatment group presented superior parameters for total motility (58.4 ± 16.9) and progressive motility (43.9 ± 18.9) in relation to the other means tested (p < 0.05) and was similar to the samples selected by the Percoll gradient in all parameters. In addition, the application of atmospheric plasma did not influence sperm selection, i.e., the use or not of atmospheric plasma does not cause improvements or ease in selection. Thus, the manufacture of a new microfluidic device was efficient in the selection of spermatozoa from sheep when compared to the Percoll gradient..
dc.description.physical81 f. : Il.
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
dc.format.mimetypepdf
dc.identifier.advisorLatteshttp://lattes.cnpq.br/4564055986199041
dc.identifier.authorLatteshttp://lattes.cnpq.br/2436132233906288
dc.identifier.bibliographicCitationFERNANDES, Beatriz Dantas. Desenvolvimento e aplicação de dispositivo microfluídico tratado com plasma atmosférico frio na seleção de espermatozoides epididimários de carneiros. 2024. 81 f. Tese (Doutorado em Ciência Animal) - Universidade Federal Rural do Semi-Árido, Mossoró, 2024.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/13117
dc.language.isopt_BR
dc.publisher.centerCentro de Ciências Agrárias - CCA
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.publisher.programPrograma de Pós-Graduação em Ciência Animal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqCIENCIAS AGRARIAS::MEDICINA VETERINARIA
dc.subject.keywordProdução in vitro
dc.subject.keywordFertilização
dc.subject.keywordReprodução
dc.subject.keywordPequenos ruminantes
dc.subject.keywordSeleção espermática
dc.subject.keywordIn vitro production
dc.subject.keywordFertilization
dc.subject.keywordReproduction
dc.subject.keywordSmall ruminants
dc.subject.keywordSperm selection
dc.titleDesenvolvimento e aplicação de dispositivo microfluídico tratado com plasma atmosférico frio na seleção de espermatozoides epididimários de carneiros
dc.title.alternativeDevelopment and application of a microfluidic device treated with cold atmospheric plasma in the selection of ram epididymal spermatozoa
dc.typeinfo:eu-repo/semantics/doctoralThesis