Efeito do diâmetro no coeficiente de descarga de sifões, em diferentes condições de carga hidráulica
| dc.contributor.advisor | Medeiros Filho, José Cipriano de | |
| dc.contributor.advisormail | depositobot@ufersa.edu.br | |
| dc.contributor.author | Fernandes, Marcos Aurélio de Paula | |
| dc.contributor.referee1 | Medeiros Filho, José Cipriano de | |
| dc.contributor.referee2 | Espínola, Francisco das Chagas da S. | |
| dc.contributor.referee3 | Nogueira, Francisco das Chagas | |
| dc.coverage.spatial | Mossoró | |
| dc.date.accessioned | 2025-10-21T18:55:30Z | |
| dc.date.available | 2025-10-21T18:55:30Z | |
| dc.date.issued | 1995-12-18 | |
| dc.description.abstract | Ensaios foram realizados no Laboratório de Hidráulica da Escola Superior de Agricultura de Mossoró (ESAM), em Mossoró - RN, visando determinar o efeito do diâmetro no coeficiente de descarga de sifões, em diferentes condições de carga hidráulica. Foram utilizados sifões de PVC flexível (SPIRAFLEX), azul transparente, de 2 m de comprimento e diâmetros nominais de 1 pol., 1 ½ pol. e 2 pol., submetidos às cargas hidráulicas de 0,05 m, 0,10 m, 0,15 m, 0,20 m, 0,25 m, 0,30 m, 0,35 m, 0,40 m, 0,45 m e 0,50 m, as quais foram estabelecidas através de um nível de mangueira e de um piezômetro. Os coeficientes de descarga foram determinados pela relação entre as vazões real e teórica, sendo as vazões reais determinadas pelo método volumétrico direto e as vazões teóricas através do produto da área média da seção transversal do sifão pela velocidade teórica do escoamento. Os resultados mostraram que o coeficiente de descarga do sifão aumentou significativamente com os aumentos do diâmetro e da carga hidráulica e que esses dois parâmetros são interdependentes, constatando-se, também, que o coeficiente de descarga foi mais influenciado pelo diâmetro que pela carga hidráulica. Para representar a função coeficiente de descarga versus carga hidráulica, foram escolhidas as equações Cd = 0,4963 + 0,2169 h - 0,5702 h² + 0,6496 h³, Cd = 0,5790 + 0,1693 h - 0,3113 h² + 0,2813 h³ e Cd = 0,5887 + 0,4085 h - 1,1912 h² + 1,2100 h³, para os diâmetros de 1 pol., 1 ½ pol. e 2 pol., respectivamente. | |
| dc.description.abstract2 | Tests were carried out at the Hydraulics Laboratory of the Mossoró College of Agriculture (ESAM), in Mossoró - RN, aiming to determine the effect of diameter on the discharge coefficient of siphons, under different hydraulic load conditions. Flexible PVC siphons (SPIRAFLEX), transparent blue, 2 m long and with nominal diameters of 1 in., 1 1/2 in. and 2 in., were used, subjected to hydraulic loads of 0.05 m, 0.10 m, 0.15 m, 0.20 m, 0.25 m, 0.30 m, 0.35 m, 0.40 m, 0.45 m and 0.50 m, which were established through a hose level and a piezometer. Discharge coefficients were determined by the ratio of actual to theoretical flow rates. Actual flow rates were determined by the direct volumetric method, and theoretical flow rates were determined by the product of the average cross-sectional area of the siphon and the theoretical flow velocity. The results showed that the discharge coefficient of the siphon increased significantly with increases in diameter and hydraulic head, and that these two parameters are interdependent. It was also found that the discharge coefficient was more influenced by diameter than by hydraulic head. To represent the discharge coefficient function versus hydraulic head, the equations Cd = 0.4963 + 0.2169 h - 0.5702 h² + 0.6496 h³, Cd = 0.5790 + 0.1693 h - 0.3113 h² + 0.2813 h³ and Cd = 0.5887 + 0.4085 h - 1.1912 h² + 1.2100 h³ were chosen, for diameters of 1 in., 1 ½ in. and 2 in., respectively. | |
| dc.description.physical | 44 f. | |
| dc.format.mimetype | ||
| dc.identifier.bibliographicCitation | FERNANDES, Marcos Aurélio de Paula. Efeito do diâmetro no coeficiente de descarga de sifões, em diferentes condições de carga hidráulica. 1995. 44 f. TCC (Graduação) - Curso de Agronomia, Centro de Ciências Agrárias - CCA, Universidade Federal Rural do Semi-Árido – UFERSA, Mossoró, 1995. | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/14300 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro de Ciências Agrárias - CCA | |
| dc.publisher.country | Brasil | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.holder | UFERSA | |
| dc.rights.license | Attribution 3.0 Brazil | en |
| dc.rights.uri | http://creativecommons.org/licenses/by/3.0/br/ | |
| dc.subject.cnpq | CIENCIAS AGRARIAS::AGRONOMIA | |
| dc.subject.keyword | Sifão | |
| dc.subject.keyword | Coeficiente de descarga | |
| dc.subject.keyword | Diâmetro | |
| dc.subject.keyword | Carga hidráulica | |
| dc.subject.keyword | Método volumétrico | |
| dc.title | Efeito do diâmetro no coeficiente de descarga de sifões, em diferentes condições de carga hidráulica | |
| dc.title.alternative | Effect of diameter on the discharge coefficient of siphons, under different hydraulic load conditions | |
| dc.type | info:eu-repo/semantics/bachelorThesis |