🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Estudo de viabilidade de sensores de oximetria e frequência cardíaca utilizando o arduino mega 2560

dc.contributor.advisorSilva Segundo, Francisco Carlos Gurgel da
dc.contributor.authorLeite, Jonhnathan Henrique Carvalho
dc.contributor.referee1Silva Segundo, Francisco Carlos Gurgel da
dc.contributor.referee2Mesquita, Marco Diego Aurélio
dc.contributor.referee3Paiva, Sâmara de Cavalvante
dc.coverage.spatialCaraúbas
dc.date.accessioned2024-01-24T20:03:44Z
dc.date.available2024-01-24T20:03:44Z
dc.date.issued2023-05-18
dc.description.abstractÉ de grande relevância o estudo de sensores de oximetria pois são amplamente utilizados para medição da saturação de oxigênio no sangue e frequência cardíaca, de forma não invasiva. A oximetria de pulso é um método comum para realizar a avaliação da função respiratória e circulatória em pessoas que apresentam diferentes condições médicas. Por isso, a proposta deste estudo é realizar uma análise de sensores utilizados em prototipagem de sistemas disponíveis no mercado, fazendo o comparativo entre eles e um equipamento comercial. A utilização de sensores tem como objetivo melhorar a qualidade de vida dos pacientes, reduzir os custos associados ao tratamento médico e desenvolver novas aplicações para esses dispositivos em diferentes áreas, como em esportes de alto desempenho, controle de processos industriais e em situações de emergência, como em acidentes de trânsito ou em locais de desastres naturais. Para realizar o estudo, foram utilizados diferentes métodos de análise, como testes de sensibilidade e avaliação da precisão dos sensores de oximetria. Após o tratamento e análise dos dados pôde-se identificar vários fatores que influenciam diretamente na sensibilidade e precisão, com isso, têm-se um controle do desempenho desses sensores.
dc.description.abstract2The study of oximetry sensors is of great relevance because they are widely used to measure oxygen saturation in the blood and heart rate, in a non-invasive way. Pulse oximetry is a common method for assessing respiratory and circulatory function in people with different medical conditions. Therefore, the purpose of this study is to analyze and perform an analysis of sensors used in prototyping systems available on the market, making a comparison between them and commercial equipment. The use of sensors aims to improve the quality of life of patients, reduce costs associated with medical treatment and develop new applications for these devices in different areas, such as high-performance sports, industrial process control and in emergency situations, such as in traffic accidents or in places of natural disasters. To carry out the study, different analysis methods were used, such as sensitivity tests and evaluation of the accuracy of oximetry sensors. After treatment and analysis of the data, it was possible to identify several factors that directly influence the sensitivity and precision, with this, there is a control of the performance of these sensors.
dc.description.physical51 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationLEITE, Jonhnathan Henrique Carvalho. Estudo de viabilidade de sensores de oximetria e frequência cardiaca utilizando o arduino mega 2560. 2023. 51 f. TCC (Graduação) - Curso de Bacharelado em Ciência e Tecnologia, Universidade Federal do Rural do Sem-Árido, Caraúbas, 2023.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/10270
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Caraúbas - CMC
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.rights.holderUFERSA
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA
dc.subject.keywordSensores
dc.subject.keywordOximetria
dc.subject.keywordSaturação de oxigênio
dc.subject.keywordFrequência cardíaca
dc.titleEstudo de viabilidade de sensores de oximetria e frequência cardíaca utilizando o arduino mega 2560
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
JonhnathanHCL_MONO.pdf
Tamanho:
830,62 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: