| dc.description.abstract | Este trabalho tem como objetivo analisar os impactos da inserção de geração distribuída (GD) em um sistema de distribuição utilizando o modelo IEEE 13-Node Distribution Test Feeder. Para isso, foi realizado um estudo em ambiente de simulação utilizando o software MATLAB, especificamente o Simulink e a biblioteca Simscape Electrical. A pesquisa investigou o comportamento de relés de sobrecorrente em cenários com e sem GD, avaliando a atuação em situações de faltas trifásicas, fluxo reverso de potência e a ocorrência de proteção cega (blind protection). Foram realizados dois cenários de simulação: o primeiro focou na análise do perfil de tensão e atuação indevida de relés em função do fluxo bidirecional causado pela GD. O segundo cenário buscou identificar a proteção cega em relés de sobrecorrente devido à posição da GD. Os resultados indicaram que a inserção de GD melhorou o perfil de tensão da rede, mas trouxe desafios para a proteção do sistema, como aumento do nível de curto-circuito e fluxo de potência reverso. Conclui-se que a GD, embora benéfica para o sistema em termos de estabilidade de tensão, pode afetar negativamente a operação da proteção de sobrecorrente não direcional, evidenciando a necessidade de adaptações nos esquemas de proteção para lidar com o novo cenário de fluxo bidirecional. | |
| dc.description.abstract2 | This work aims to analyze the impacts of distributed generation (DG) integration in a distribution system using the IEEE 13-Node Distribution Test Feeder model. For this purpose, a simulation study was conducted using MATLAB software, specifically Simulink and the Simscape Electrical library. The research investigated the behavior of overcurrent relays in scenarios with and without DG, evaluating their performance in cases of three-phase faults, reverse power flow, and the occurrence of blind protection. Two simulation scenarios were performed: the first focused on analyzing the voltage profile and improper relay operation due to the bidirectional flow caused by DG. The second scenario aimed to identify blind protection in overcurrent relays due to the DG's location in the system. The results indicated that the integration of DG improved the network's voltage profile but posed challenges to the system’s protection, such as increased short-circuit levels and reverse power flow. It was concluded that, although DG is beneficial to the system in terms of voltage stability, it can negatively affect the operation of non-directional overcurrent protection, highlighting the need for adaptations in protection schemes to address the new bidirectional flow scenario. | |
| dc.description.physical | 64 f. | |
| dc.format.mimetype | ||
| dc.identifier.authorLattes | http://lattes.cnpq.br/6801394916566334 | |
| dc.identifier.bibliographicCitation | LILIOSO, Ana Carla. Análise do impacto da operação descentralizada da Geração Distribuída em um sistema de distribuição durante eventos de falta. 2024. 64 f. TCC (Graduação) - Curso de Engenharia Elétrica. Universidade Federal Rural do Semi - Árido, Caraúbas, 2024. | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/13431 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro Multidisciplinar de Caraúbas - CMC | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | DEPARTAMENTO DE ENGENHARIAS | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.holder | UFERSA | |
| dc.rights.license | Attribution-ShareAlike 3.0 Brazil | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/3.0/br/ | |
| dc.subject.cnpq | ENGENHARIAS::ENGENHARIA ELETRICA | |
| dc.subject.keyword | Geração distribuída | |
| dc.subject.keyword | Modelagem de sistemas | |
| dc.subject.keyword | Sistema de proteção | |
| dc.title | Análise do impacto da operação descentralizada da Geração Distribuída em um sistema de distribuição durante eventos de falta. | |
| dc.title.alternative | Analysis of the Impact of Decentralized Operation of Distributed Generation on a Distribution System During Fault Events. | |