🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Proposta de detecção de cobre na água por sensores com ressonador de anel fendido

dc.contributor.advisorSilva, Isaac Barros Tavares da
dc.contributor.authorMelo, Mateus Henrique Amorim Medeiros
dc.contributor.referee1Silva, Isaac Barros Tavares da
dc.contributor.referee2Holanda, Samanta Mesquita de
dc.contributor.referee3Andrade, Humberto Dionísio de
dc.contributor.referee4Queiroz Júnior, Idalmir de Souza
dc.contributor.referee5Oliveira, Elias Marques Ferreira de
dc.coverage.spatialMossoró
dc.date.accessioned2025-07-02T18:10:09Z
dc.date.available2025-07-02T18:10:09Z
dc.date.issued2024-01-31
dc.description.abstractA água é um recurso cada vez mais escasso e, para manutenção da sua qualidade, ela precisa ser monitorada. Um dos seus contaminantes é o cobre. Os órgãos nacionais e internacionais fornecem limites máximos para a concentração desse metal pesado e técnicas como a espectrometria são as mais utilizadas para medi-la. Recentemente, técnicas de identificação de materiais pela sua caracterização dielétrica tem sido alvos de estudos, sobretudo os que realizam essa caracterização a partir de parâmetros como a frequência de ressonância de antenas de microfita. Este trabalho tem como objetivo desenvolver um sensor que determine a concentração de cobre em uma amostra de água contaminada a partir do deslocamento da frequência ressonante na curva do coeficiente de reflexão. A partir de uma revisão bibliográfica foram propostas três geometrias de Antenas com Ressonador de Anel Fendido Complementar. Esses dispositivos foram modelados e tiveram suas curvas de coeficiente de reflexão simuladas. Eles também foram fabricados em três protótipos e cada um deles teve a curva de coeficiente de reflexão medida três vezes. Os resultados medidos e simulados obtiveram valores próximos e corresponderam à tendência fundamentada na teoria de que a diminuição da permissividade pelo aumento da concentração de cobre na água provoca um aumento da frequência ressonante. Nas simulações, a faixa de 0 mg/L a 2 mg/L foi a que obteve o maior deslocamento de frequência na média de todos os protótipos. Nas medições, nessa faixa ocorreu o segundo maior deslocamento. Os deslocamentos de frequência de ressonância foram analisados a partir de regressão linear, obtendo-se modelos de retas ajustadas, cuja inclinação e valor de R² foram interpretados como, respectivamente, sensibilidade do protótipo e confiabilidade do modelo. Os modelos dos protótipos circulares foram os mais sensíveis e os quadrados os mais confiáveis. Considerando o passo da medição de 4,79 MHz, os formatos circular, octogonal e quadrado alcançaram a sensibilidade capaz de verificar uma mudança de concentração de, respectivamente, 145 µg/L, 293 µg/L e 523 µg/L de cobre na água, sendo, então, todos suficientes para detectar os limites máximos estabelecidos pelos órgãos.
dc.description.abstract2The water is an increasingly scarce resource and, for the maintenance of its quality, it needs to be monitored. One of its contaminants is copper. National and international organizations provide maximum limits for the concentration of this heavy metal, and techniques such as spectrometry are the most commonly used to measured it. Recently, techniques for identifying materials based on their dielectric characterization have been the subject of studies, particularly those that perform this characterization using parameters such as the resonance frequency of microstrip antennas. This work aims to develop a sensor that determines the concentration of copper in a sample of contaminated water based on the shift in resonant frequency in the reflection coefficient curve. Three geometries of Complementary Split Ring Resonator antennas were proposed based on a literature review. These devices were modeled and their reflection coefficient curves were simulated. Each one of them was also manufactured in three prototypes, and each of them had the reflection coefficient curve measured three times. The measured and simulated results obtained values close to each other and corresponded to the trend based on the theory that the decrease in permittivity due to the increase in copper concentration in water causes an increase in resonant frequency. In simulations, the range from 0 mg/L to 2 mg/L yielded the highest frequency shift on average of all prototypes. In measurements, this range exhibited the second-highest shift, behind only the from 4 mg/L to 6 mg/L. Resonance frequency shifts were analyzed using linear regression, obtaining fitted line models, whose slope and R² value were interpreted as prototype sensitivity and model reliability, respectively. The circular prototypes models were the most sensitive, while the square ones were the most reliable. Considering the measurement step of 4.79 MHz, the circular, octagonal, and square shapes achieved the sensitivity to detect a concentration change of 145 µg/L, 293 µg/L, and 523 µg/L of copper in the water, respectively. Therefore, all of them are sufficient to detect the maximum limits established by the authorities.
dc.description.physical64 f. : Il.
dc.format.mimetypepdf
dc.identifier.advisorLatteshttp://lattes.cnpq.br/7304355962395872
dc.identifier.authorLatteshttp://lattes.cnpq.br/1882312312280197
dc.identifier.bibliographicCitationMELO, Mateus Henrique Amorim Medeiros. Proposta de detecção de cobre na água por sensores com ressonador de anel fendido. 2024. 64 f. Dissertação (Mestrado em Engenharia Elétrica)- Universidade Federal Rural do Semi-Árido, Mossoró, 2024. Disponível em: https://repositorio.ufersa.edu.br. Acesso em: 25 jun. 2025.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/13365
dc.language.isopt_BR
dc.publisher.centerCentro de Engenharias - CE
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétrica
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA ELETRICA
dc.subject.keywordCSRR
dc.subject.keywordCaracterização dielétrica
dc.subject.keywordSensoriamento de micro-ondas
dc.subject.keywordDeslocamento de frequência de ressonância
dc.subject.keywordMonitoramento de qualidade da água
dc.subject.keywordDieletric characterization
dc.subject.keywordMicrowave sensing
dc.subject.keywordResonance frequency shift
dc.subject.keywordWater quality monitoring
dc.titleProposta de detecção de cobre na água por sensores com ressonador de anel fendido
dc.title.alternativeProposal for detection of copper in water proposal by split-ring ressonator sensors
dc.typeinfo:eu-repo/semantics/masterThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
MateusHAMM_Dissertação.pdf
Tamanho:
3,32 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: