Análise da não-conformidade da resistência à compressão em estruturas de concreto armado.
| dc.contributor.advisor | Santos Junior, Gilvan Bezerra dos | |
| dc.contributor.author | Gondim, Antonio Juscelino de Oliveira | |
| dc.contributor.referee1 | Santos Junior, Gilvan Bezerra dos | |
| dc.contributor.referee2 | Marinho, Renata de Oliveira | |
| dc.contributor.referee3 | Oliveira, Leonardo Henrique Borges de | |
| dc.coverage.spatial | Caraúbas | |
| dc.date.accessioned | 2024-05-03T17:05:02Z | |
| dc.date.available | 2024-05-03T17:05:02Z | |
| dc.date.issued | 2024-04-19 | |
| dc.description.abstract | As estruturas de concreto armado devem apresentar resistência à compressão satisfatória, tendo em vista a necessidade de ser uma edificação eficiente, segura e que possa ter durabilidade. E o estudo da não-conformidade dessa propriedade mecânica permite analisar a integralidade estrutural de uma edificação quando as especificações do projeto estrutural não estão sendo alcançadas. É possível inferir que as não-conformidades podem surgir de etapas iniciais da execução, como por exemplo a seleção dos insumos ou até mesmo o controle de qualidade. Esse problema pode surgir de ações como: um mal dimensionamento dos elementos estruturais, da execução inadequada da concretagem, da falta colocação de armadura. Assim, o presente estudo versa sobre análise das implicações no comportamento estrutural após o surgimento das não-conformidades, bem como oferece as soluções para a correção das falhas que surgiram. Para execução do trabalho, realizou-se modelagem de projeto estrutural de um edifício de pequeno porte ou seja, uma edificação modesta, de até cinco pavimentos, utilizando o programa CYPECAD® (2019). Sendo uma estrutura de quatro pavimentos, com vinte e quatro pilares, sessenta e oito vigas e quatro grupos de pisos de lajes. Por meio da utilização de planilhas realizou-se uma análise paramétrica com a variação da resistência característica à compressão em todos os elementos estruturais para análise das não-conformidades. Algumas não-conformidades foram identificadas, baseando-se pelos resultados encontrados ao se reduzir o fck para 15 MPa, o que resultou-se em um aumento significativo na taxa de armadura, que foram: 78% no pilar P13 do 1º pavimento, 18% na viga do 2º pavimento e 20% na laje do 1º pavimento. E ações de reforços como aumento da taxa aço e implantação de armadura negativa, foram algumas das sugestões. | |
| dc.description.abstract2 | Reinforced concrete structures must have satisfactory compressive strength, given the need to be an efficient, safe and durable building. And the study of the non-conformity of this mechanical property allows us to analyze the structural integrity of a building when the structural design specifications are not being achieved. It is possible to infer that non-conformities may arise from initial stages of execution, such as the selection of inputs or even quality control. This problem can arise from actions such as: poor dimensioning of structural elements, inadequate execution of concreting, lack of reinforcement placement. Thus, the present study focuses on analyzing the implications for structural behavior after the emergence of non-conformities, as well as offering solutions for correcting the flaws that have arisen. To carry out the work, structural design modeling of a small building was carried out, that is, a modest building, up to five floors, using the CYPECAD® program (2019). It is a four-story structure, with twenty-four pillars, sixty-eight beams and four groups of slab floors. Using spreadsheets, a parametric analysis was carried out with the variation of the characteristic compressive strength in all structural elements to analyze non-conformities. Some non-conformities were identified, based on the results found when reducing the fck to 15 MPa, which resulted in a significant increase in the reinforcement rate, which were: 78% in pillar P13 on the 1st floor, 18% on the beam of the 2nd floor and 20% on the slab of the 1st floor. And reinforcement actions such as increasing the steel rate and implementing negative reinforcement were some of the suggestions. | |
| dc.description.physical | 61 f. | |
| dc.format.mimetype | ||
| dc.identifier.bibliographicCitation | GONDIM, Antonio Juscelino de Oliveira. Análise da não-conformidade da resistência à compressão em estruturas de concreto armado. 2024. 61 f. Monografia (Graduação) - Curso de Engenharia Civil, Departamento de Engenharias, Universidade Federal Rural do Semi-Árido, Caraúbas, 2024. | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/10792 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro Multidisciplinar de Caraúbas - CMC | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | Departamento de Engenharias | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | en |
| dc.rights.holder | UFERSA | |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/3.0/br/ | |
| dc.subject.cnpq | ENGENHARIAS::ENGENHARIA CIVIL | |
| dc.subject.keyword | Dimensionamento | |
| dc.subject.keyword | Edificação | |
| dc.subject.keyword | Segurança | |
| dc.subject.keyword | Taxa de armadura | |
| dc.title | Análise da não-conformidade da resistência à compressão em estruturas de concreto armado. | |
| dc.type | info:eu-repo/semantics/bachelorThesis |
