Tempo de retenção do ametryn em função do ph da fase móvel em HPLC
| dc.contributor.advisor | Braga, Daniely Formiga | |
| dc.contributor.author | Araújo, Ana Gabriella Duarte de | |
| dc.contributor.referee1 | Braga, Daniely Formiga | |
| dc.contributor.referee2 | Chagas, Paulo Sergio Fernandes Das | |
| dc.contributor.referee3 | Lopes, Welder de Araújo Rangel | |
| dc.contributor.referee4 | Silva, Guymmann Clay da | |
| dc.coverage.spatial | Caraúbas | |
| dc.date.accessioned | 2024-08-14T11:44:19Z | |
| dc.date.available | 2024-08-14T11:44:19Z | |
| dc.date.issued | 2015-12-07 | |
| dc.description.abstract | Com o intuito de minimizar o uso de Acetonitrila visando diminuir os problemas ambientais e os custos para aquisição deste solvente em HPLC, realizou-se um experimento com o objetivo de avaliar o tempo de retenção do ametryn em função do pH da fase móvel. Utilizou-se o delineamento inteiramente casualizando, em esquema fatorial 4 x 5, com três repetições, sendo o primeiro fator composto pelas proporções das fases móveis (soluções tamponadas : acetonitrila): 55:45; 60:40; 65:35 e 70:30 (v/v) , e o segundo fator, composto pelo pH da fase móvel: 3,0; 3,5; 4,0; 4,5 e 5,0. As soluções tampões de acido acético e acetato de sódio foram preparadas na concentração de 0,1 m/L. Na determinação quantitativa do Ametryn e avaliação do tempo de retenção foi utilizado um sistema de cromatografia líquida de alta eficiência, modelo Varian ProStar 325, detector UV-Vis, coluna de aço inox (Varian Microsorb 100 -3 C18, 100 mm x 4,6 mm d.i.). Para preparo da amostra foi utilizando um padrão analítico do Ametryn (98,5% de pureza) na concentração de 50 ppm. Os resultados indicam que o aumento na proporção de acetonitrila promoveu decréscimo no tempo de retenção do ametryn, independente do pH da fase móvel; menor tempo de retenção (2,89 min) foi obtido na proporção de 55:45 (v/v) de solução tamponada em pH 3,0 e acetonitrila e com o aumento do pH da fase móvel, houve aumento do tempo de retenção com máximos de 11,06, 7,17, 5,08 e 3,82 minutos, utilizando-se as proporções de 30,45,40 e 45% de acetonitrila, respectivamente. | |
| dc.description.abstract2 | In order to minimize the use of acetonitrile in order to decrease environmental problems and costs for the acquisition of this solvent in HPLC, there was an experiment with the objective of evaluating the ametryn retention time depending on the pH of the mobile phase. We used the design entirely casualizando in a factorial 4 x 5 with three replications, the first factor composed of the proportions of mobile phases (buffered solutions: acetonitrile): 55:45; 60:40; 65:35 and 70:30 (v / v) and the second factor consisting of the pH of the mobile phase: 3.0; 3.5; 4.0; 4.5 and 5.0. The buffer solutions of acetic acid and sodium acetate were prepared at a concentration of 0.1 m / l. In the quantitative determination of ametryn and retention time evaluation we used a liquid chromatography system of high efficiency, model Varian ProStar 325 UV-Vis detector, stainless steel column (Varian Microsorb 100 C18 -3, 4.6 x 100 mm mm id). To prepare the sample using an analytical standard ametryn (98.5% purity) at a concentration of 50 ppm. The results indicate that increasing the proportion of acetonitrile promoted ametryn decrease in retention time, regardless of the pH of the mobile phase; lower retention time (2.89 min) was obtained at a ratio of 55:45 (v / v) buffered solution at pH 3.0 and acetonitrile and increasing the pH of the mobile phase was increased retention time of Maximum 11.06, 7.17, 5.08 and 3.82 minutes, using the proportions of 30, 45, 40 and 45% acetonitrile respectively. | |
| dc.description.physical | 22 f. | |
| dc.format.mimetype | ||
| dc.identifier.bibliographicCitation | ARAÚJO, Ana Gabriella Duarte de. Tempo de retenção do ametryn em função do ph da fase móvel em HPLC. 2015. 22 f. TCC (Graduação) - Curso de Bacharelado em Ciência e Tecnologia, Universidade Federal Rural do Semi-Árido, Caraúbas, 2015. | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/11247 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro Multidisciplinar de Caraúbas - CMC | |
| dc.publisher.country | Brasil | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | en |
| dc.rights.holder | UFERSA | |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/3.0/br/ | |
| dc.subject.cnpq | CIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA | |
| dc.subject.keyword | Cromatografia líquida | |
| dc.subject.keyword | Acetonitrila | |
| dc.subject.keyword | Herbicida | |
| dc.title | Tempo de retenção do ametryn em função do ph da fase móvel em HPLC | |
| dc.type | info:eu-repo/semantics/bachelorThesis |