🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Aplicação da Matriz GUT para classificação das manifestações patológicas em escolas estaduais de Barão de Grajaú- MA

dc.contributor.advisorHenriques, Glauco Fonsêca
dc.contributor.advisormailglauco.fonseca@ufersa.edu.br
dc.contributor.authorMorais, Cailany Bezerra
dc.contributor.referee1Henriques, Glauco Fonsêca
dc.contributor.referee2Silva, Leonete Cristina de Araújo Ferreira Medeiros
dc.contributor.referee3Linhares, Edna Lucia da Rocha
dc.contributor.referee4Marinho, Renata de Oliveira
dc.coverage.spatialCaraúbas
dc.date.accessioned2025-03-27T18:19:43Z
dc.date.available2025-03-27T18:19:43Z
dc.date.issued2025-02-14
dc.description.abstractAtualmente, a construção civil tem se desenvolvido rapidamente, trazendo novas técnicas e materiais que melhoram a qualidade das edificações. Porém, ainda é enfrentado problemas frequentes de manifestações patológicas, principalmente em construções públicas, que afetam a durabilidade e a segurança dessas estruturas. Esses problemas se agravam em situações de cidades de menor porte, dado a baixa fiscalização e recurso financeiro. Assim, o estudo foi realizado em duas escolas públicas estaduais: Centro de Ensino Aristides Lobão e o Centro de Ensino Ney Braga, localizadas na área urbana do município de Barão de Grajaú - MA. Para a avaliação utilizou-se a matriz GUT. As manifestações patológicas mais comuns encontradas foram descascamento e desplacamento do revestimento, eflorescência, infiltração, fissuras, rachaduras, manchas, bolor e cupim. Na escola Centro de Ensino Aristides Lobão as manifestações patológicas mais críticas foram as infiltrações juntamente com manchas/bolor e na escola Centro de Ensino Ney Braga foram manchas/bolor e descascamento do revestimento, ambas escolas sendo classificadas em um grau de risco intermediário. A falta de manutenção preventiva, falhas na impermeabilização e a alta umidade foram fatores determinantes para o desgaste das estruturas de ambas as escolas. Destaca-se a urgência de implementar um plano de manutenção contínuo, com revisões periódicas, a fim de preservar as edificações e garantir a segurança dos usuários, evitando gastos inesperados com reparos emergenciais.
dc.description.abstract2Currently, the construction industry has been rapidly developing, introducing new techniques and materials that improve the quality of buildings. However, frequent issues related to pathological manifestations are still encountered, particularly in public constructions, which affect the durability and safety of these structures. These problems are more pronounced in smaller cities due to limited oversight and financial resources. Thus, the study was conducted at two public state schools: Centro de Ensino Aristides Lobão and Centro de Ensino Ney Braga, located in the urban area of the municipality of Barão de Grajaú - MA. The GUT matrix was used for the evaluation. The most common pathological manifestations found were peeling and detachment of the cladding, efflorescence, infiltration, fissures, cracks, stains, mold, and termites. In the Centro de Ensino Aristides Lobão school, the most critical pathological manifestations were infiltration along with stains/mold, while at the Centro de Ensino Ney Braga school, they were stains/mold and cladding peeling. Both schools were classified with an intermediate risk level. The lack of preventive maintenance, failures in waterproofing, and high humidity were determining factors for the wear of the structures at both schools. The urgency of implementing a continuous maintenance plan with periodic reviews is highlighted to preserve the buildings and ensure user safety, avoiding unexpected expenses for emergency repairs.
dc.description.physical62 f.
dc.format.mimetypepdf
dc.identifier.advisorLatteshttp://lattes.cnpq.br/9711586891571031
dc.identifier.authorLatteshttp://lattes.cnpq.br/7028076099462550
dc.identifier.bibliographicCitationMORAIS, Cailany Bezerra. Aplicação da Matriz GUT para Classificação das Manifestações Patológicas em Escolas Estaduais de Barão de Grajaú- MA. 2025. 62 f. TCC (Graduação) - Curso de Interdisciplinar em Ciência e Tecnologia, Universidade Federal Rural do Semi-Árido, Caraúbas - RN, 2025.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/12764
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Caraúbas - CMC
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Ciência e Tecnologia
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA
dc.subject.keywordEngenharia diagnóstica
dc.subject.keywordVida útil
dc.subject.keywordPatologia das construções
dc.titleAplicação da Matriz GUT para classificação das manifestações patológicas em escolas estaduais de Barão de Grajaú- MA
dc.title.alternativeApplication of the GUT Matrix for the Classification of Pathological Manifestations in State Schools of Barão de Grajaú - MA
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
CailanyBM_MONO.pdf
Tamanho:
2,42 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: