🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Avaliação estrutural preliminar do reservatório de abastecimento de água no município de João Dias no Rio Grande do Norte com foco em sinais de corrosão eletroquímica em concreto

dc.contributor.advisorDias, Sanderlir Silva
dc.contributor.advisormailsanderlir.dias@ufersa.edu.br
dc.contributor.authorSoares, Hudson Marques
dc.contributor.referee1Dias, Sanderlir Silva
dc.contributor.referee2Urcezino, Amanda da Silva Cardoso
dc.contributor.referee3Júnior, José Vidal
dc.coverage.spatialPau dos Ferros
dc.date.accessioned2026-01-20T19:06:39Z
dc.date.available2026-01-20T19:06:39Z
dc.date.issued2025-12-19
dc.description.abstractAs estruturas de concreto armado são amplamente utilizadas em obras de infraestrutura devido à sua resistência e à sua durabilidade. No entanto, ao longo do tempo, essas estruturas estão sujeitas a processos de deterioração, sendo a corrosão das armaduras uma das principais manifestações patológicas, capaz de comprometer a segurança estrutural, a durabilidade e a viabilidade econômica das construções. Nesse contexto, este trabalho teve como objetivo realizar uma avaliação estrutural preliminar de um reservatório elevado de abastecimento de água localizado no município de João Dias – RN, com foco na identificação de manifestações patológicas associadas à corrosão em elementos de concreto armado e componentes metálicos. A metodologia adotada consistiu em uma inspeção visual direta, de caráter qualitativo e descritivo, seguindo as recomendações da norma ABNT NBR 16747:2020. Foram realizados registros fotográficos e observações sistemáticas da estrutura, sem a utilização de ensaios destrutivos ou equipamentos de medição, permitindo a identificação de fissuras, desplacamento do cobrimento, armaduras expostas e corrosão em tubulações metálicas. Os resultados evidenciaram a presença de patologias típicas associadas à corrosão por carbonatação e à ação de agentes ambientais, decorrentes da idade da estrutura, da exposição contínua às intempéries e da ausência de manutenção preventiva ao longo dos anos. As manifestações observadas indicam riscos estruturais, econômicos e de segurança, especialmente por se tratar de uma estrutura localizada em área urbana e próxima a equipamentos públicos. Concluiu-se que a estrutura avaliada apresenta sinais de deterioração que exigem intervenções corretivas e a implementação de medidas preventivas, visando à recuperação da integridade estrutural, ao prolongamento da vida útil do reservatório e à garantia da segurança da população atendida. O estudo reforça a importância da inspeção periódica e da manutenção preventiva em estruturas de concreto armado destinadas ao uso público.
dc.description.abstract2Reinforced concrete structures are widely used in infrastructure projects due to their strength and durability. However, over time, these structures are subject to deterioration processes, with reinforcement corrosion being one of the main pathological manifestations, capable of compromising the structural safety, durability, and economic viability of constructions. In this context, this work aimed to carry out a preliminary structural assessment of an elevated water supply reservoir located in the municipality of João Dias – RN, focusing on the identification of pathological manifestations associated with corrosion in reinforced concrete elements and metallic components. The methodology adopted consisted of a direct visual inspection, of a qualitative and descriptive nature, following the recommendations of ABNT NBR 16747:2020. Photographic records and systematic observations of the structure were carried out, without the use of destructive tests or measuring equipment, allowing the identification of cracks, spalling of the cover, exposed reinforcement, and corrosion in metallic pipes. The results revealed the presence of typical pathologies associated with carbonation corrosion and the action of environmental agents, resulting from the age of the structure, continuous exposure to weathering, and the absence of preventive maintenance over the years. The observed manifestations indicate structural, economic, and safety risks, especially since it is a structure located in an urban area and close to public facilities. It was concluded that the evaluated structure shows signs of deterioration that require corrective interventions and the implementation of preventive measures, aiming at the recovery of structural integrity, the extension of the reservoir's lifespan, and the guarantee of the safety of the population served. The study reinforces the importance of periodic inspection and preventive maintenance in reinforced concrete structures intended for public use.
dc.description.physical38 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationSOARES, Hudson Marques. Avaliação estrutural preliminar do reservatório de abastecimento de água no município de João Dias no Rio Grande do Norte com foco em sinais de corrosão eletroquímica em concreto. 2025. 38 f. Monografia (Bacharelado Interdisciplinar em Ciência e tecnologia ) – Centro Multidisciplinar de Pau dos Ferros, Universidade Federal Rural do Semi-Árido, Pau dos Ferros, 2025.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/14915
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Pau dos Ferros - CMPF
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Ciências Exatas e Naturais - DECEN
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA
dc.subject.keywordCorrosão
dc.subject.keywordConcreto armado
dc.subject.keywordDurabilidade
dc.subject.keywordReservatórios de água
dc.subject.keywordPatologias estruturais
dc.subject.keywordCorrosion
dc.subject.keywordReinforced concrete
dc.subject.keywordDurability
dc.subject.keywordWater reservoirs
dc.subject.keywordStructural pathologies
dc.titleAvaliação estrutural preliminar do reservatório de abastecimento de água no município de João Dias no Rio Grande do Norte com foco em sinais de corrosão eletroquímica em concreto
dc.title.alternativePreliminary structural assessment of the water supply reservoir in the municipality of João Dias, Rio Grande do Norte, focusing on signs of corrosion electrochemistry in concrete
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
HudsonMS_MONO.pdf
Tamanho:
1,86 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: