🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Estudo de caso sobre corrosão em estruturas de concreto armado em uma residência unifamiliar, uma igreja e prédio multifamiliar localizados na cidade de Pau dos Ferros - RN

dc.contributor.advisorRamos, Josy Eliziane Torres
dc.contributor.authorOliveira, Gabryel Francisco Barros de
dc.contributor.referee1Figueredo, Kytéria Sabina Lopes de
dc.contributor.referee2Dias, Sanderlir Silva
dc.coverage.spatialPau dos Ferros
dc.date.accessioned2024-12-20T14:17:05Z
dc.date.available2024-12-20T14:17:05Z
dc.date.issued2024-10-24
dc.description.abstractA corrosão de armaduras é um dos processos degradantes com maior incidência nas estruturas de concreto armado. Para que possa acontecer, a corrosão precisa de um conjunto de fatores que tornam o ambiente favorável, são eles: presença de água, de ar, área anódica, área catódica, um condutor metálico (armadura) e em eletrólito (solução aquosa existente no concreto). Este estudo analisou a corrosão presente nas estruturas de concreto armado em residências, prédio comerciais e alguns locais de muitas visitações na cidade de Pau dos Ferros/RN. Foram realizados estudos e pesquisas sobre o tema bem como visitas aos locais, para aprofundamento do estudo corrosivo nas estruturas, sendo assim evidenciado um estado de deterioração muito avançado, resultado de um processo corrosivo quem em ambos os casos se instauraram ao longo de alguns anos, ficando, de forma evidente a despassivação do aço por carbonatação e por cloretos provocando fissuras paralelas na direção das barras principais, fissuras paralelas na direção dos estribos e desplacamento da cobertura de concreto e exposição da armadura. A pesquisa neste estudo, proporcionou um entendimento aprofundado sobre os tipos de corrosão, sendo a mais comum em estruturas de concreto armado, a corrosão eletroquímica, mostrando fatores que potencializaram os danos provocados nas peças estruturais proporcionando uma melhor tomada de decisão. Como resultado, observa-se que a falta de entendimento sobre como o ocorre o processo corrosivo e a falta de mão de obra qualificada potencializam o não cumprimento da vida útil de projeto, prevista em norma, fazendo assim, com que obras recentes, já demonstrem muitas manifestações patológicas. Este estudo nos forneceu conhecimento suficiente para propor soluções adequadas capaz de prevenir e corrigir tais acontecimentos patológicos.
dc.description.abstract2The corrosion of reinforcement bars is one of the most degrading processes affecting reinforced concrete structures. For corrosion to occur, a combination of factors must create a favorable environment: the presence of water, air, an anodic area, a cathodic area, a metallic conductor (reinforcement), and an electrolyte (aqueous solution present in the concrete). This study analyzed the corrosion found in reinforced concrete structures in residences, commercial buildings, and frequently visited locations in Pau dos Ferros/RN. Studies and research on the topic were conducted, along with site visits, to deepen the understanding of the corrosive process in structures. A highly advanced state of deterioration was evident, resulting from a corrosive process that took place over several years. Despassivation of the steel due to carbonation and chlorides caused parallel cracks along the main bars, parallel cracks along the stirrups, and spalling of the concrete cover, exposing the reinforcement. This research provided an in-depth understanding of corrosion types, with electrochemical corrosion being the most common in reinforced concrete structures. It highlighted factors that amplified the damage to structural elements, aiding in better decision-making. Consequently, it was observed that a lack of understanding about the corrosive process and insufficiently skilled labor contributed to not meeting the project's expected service life, as prescribed by standards. This led to recent constructions showing significant pathological manifestations. This study equipped us with sufficient knowledge to propose suitable solutions to prevent and correct such pathological occurrences.
dc.description.physical74 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationOLIVEIRA, Gabryel Francisco Barros de. Estudo de caso sobre corrosão em estruturas de concreto armado em uma residência unifamiliar, uma igreja e prédio multifamiliar localizados na cidade de Pau dos Ferros - RN. 2024. 74 f. Monografia (Graduação em Ciência e tecnologia) - Centro Multidisciplinar de Pau dos Ferros, Universidade Federal Rural do Semi-Árido, Pau dos Ferros, 2024.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/12101
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Pau dos Ferros - CMPF
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-NoDerivs 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::TECNOLOGIA DA INFORMACAO
dc.subject.keywordCorrosão
dc.subject.keywordConcreto
dc.subject.keywordCarbonatação
dc.subject.keywordCloretos
dc.subject.keywordPatologia
dc.titleEstudo de caso sobre corrosão em estruturas de concreto armado em uma residência unifamiliar, uma igreja e prédio multifamiliar localizados na cidade de Pau dos Ferros - RN
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
GabryelFBO_MONO.pdf
Tamanho:
2,98 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: