Eficiência e limitações de sistemas de microgeração fotovoltaica: estudo de caso no Rio Grande do Norte e comparativo regional
| dc.contributor.advisor | Coelho, Rodrigo de Almeida | |
| dc.contributor.advisormail | rodrigo.coelho@ufersa.edu.br | |
| dc.contributor.author | Oliveira, Marcelo Targino de | |
| dc.contributor.coadvisor | Lima, Érica Mangueira | |
| dc.contributor.referee1 | Coelho, Rodrigo de Almeida | |
| dc.contributor.referee2 | Lima, Érica Mangueira | |
| dc.contributor.referee3 | Oliveira, Adriano Costa de | |
| dc.contributor.referee4 | Freitas, Antônio Alisson Alencar | |
| dc.coverage.spatial | Caraúbas | |
| dc.date.accessioned | 2026-02-03T12:01:41Z | |
| dc.date.available | 2026-02-03T12:01:41Z | |
| dc.date.issued | 2025-12-19 | |
| dc.description.abstract | A expansão da microgeração fotovoltaica no Brasil, impulsionada pelo marco regulatório da geração distribuída, tem enfrentado desafios técnicos que comprometem o desempenho operacional de sistemas conectados à rede elétrica. Este trabalho teve como objetivo realizar um estudo de caso sobre as variações de tensão provenientes de um sistema de microgeração instalado no interior do Rio Grande do Norte, identificando os principais fatores que influenciam essas variações, analisando dados operacionais em diferentes condições e avaliando o impacto na qualidade da energia fornecida. O sistema analisado apresentou desligamentos recorrentes causados por sobretensão desde sua energização, comprometendo tanto a geração de energia quanto a continuidade operacional dos equipamentos conectados à instalação. A metodologia adotou abordagem de natureza aplicada com enfoque exploratório e descritivo, combinando medições em campo, monitoramento remoto via plataforma do fabricante e comparação com outras usinas de capacidade similar na região Nordeste. Foram realizadas inspeções termográficas, medições sistemáticas de tensão em diferentes pontos da instalação e avaliação de curvas de geração ao longo do período de comissionamento. A investigação revelou que a causa raiz dos problemas residia na combinação entre características inadequadas da rede de distribuição local e a configuração da infraestrutura de conexão, especificamente relacionada à distância significativa entre o inversor e o padrão de entrada. Foram implementadas múltiplas intervenções técnicas incluindo ajustes paramétricos no inversor, ativação de funções de proteção contra sobretensão, modificação da derivação do transformador de distribuição, substituição dos cabos de interligação por condutores de maior seção e adequação da string box. O estudo demonstrou que soluções isoladas foram insuficientes para resolver o problema, sendo necessária abordagem sistêmica para alcançar estabilidade operacional. O comparativo com outras instalações mostrou que a usina estudada apresentou os maiores níveis de sobretensão entre todas as unidades avaliadas, confirmando que a extensão do circuito alimentador constitui fator crítico no desempenho. Os resultados indicaram que o funcionamento adequado não depende exclusivamente da capacidade instalada, mas é fortemente influenciado pela infraestrutura de conexão e pelos níveis de tensão fornecidos pela concessionária. | |
| dc.description.abstract2 | The expansion of photovoltaic microgeneration in Brazil, driven by the regulatory framework for distributed generation, has faced technical challenges that compromise the operational performance of systems connected to the electrical grid. This study aimed to conduct a case study on voltage variations originating from a microgeneration system installed in the interior of Rio Grande do Norte, identifying the main factors influencing these variations, analyzing operational data under different conditions, and evaluating the impact on the quality of supplied energy. The analyzed system exhibited recurrent shutdowns caused by overvoltage since commissioning, compromising both energy generation and the continuous operation of the connected equipment. The methodology adopted an applied approach with exploratory and descriptive focus, combining field measurements, remote monitoring via the manufacturer's platform, and comparison with other plants of similar capacity in the Northeast region. Thermographic inspections, systematic voltage measurements at different points in the installation, and evaluation of generation curves throughout the commissioning period were performed. The investigation revealed that the root cause of the problems lay in the combination of inadequate characteristics of the local distribution network and the connection infrastructure configuration, specifically related to the significant distance between the inverter and the connection point. Multiple technical interventions were implemented, including inverter parameter adjustments, activation of overvoltage protection functions, modification of the distribution transformer tap, replacement of interconnection cables with conductors of larger cross-section, and adaptation of the string box. The study demonstrated that isolated solutions were insufficient to solve the problem, requiring a systemic approach to achieve operational stability. Comparison with other installations showed that the studied plant experienced the highest overvoltage levels among all evaluated units, confirming that the length of the feeder circuit is a critical factor in performance. The results indicated that proper operation does not depend exclusively on installed capacity but is strongly influenced by the connection infrastructure and the voltage levels supplied by the utility. | |
| dc.description.physical | 76 f. | |
| dc.format.mimetype | ||
| dc.identifier.advisorLattes | http://lattes.cnpq.br/1211516714990564 | |
| dc.identifier.authorLattes | https://lattes.cnpq.br/9742438256863834 | |
| dc.identifier.bibliographicCitation | OLIVEIRA, Marcelo Targino de. Eficiência e limitações de sistemas de microgeração fotovoltaica: estudo de caso no Rio Grande do Norte e comparativo regional. 2025. 76 f. TCC (Graduação) - Bacharelado em Engenharia Elétrica, Universidade Federal Rural do Semi-Árido, Caraúbas, 2025. | |
| dc.identifier.coadvisorLattes | http://lattes.cnpq.br/0530843719588041 | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/15006 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro Multidisciplinar de Caraúbas - CMC | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | Departamento de Engenharias - DE | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.holder | UFERSA | |
| dc.rights.license | Attribution-ShareAlike 3.0 Brazil | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/3.0/br/ | |
| dc.subject.cnpq | ENGENHARIAS::ENGENHARIA ELETRICA | |
| dc.subject.keyword | Comissionamento | |
| dc.subject.keyword | Geração distribuída | |
| dc.subject.keyword | Microgeração fotovoltaica | |
| dc.subject.keyword | Qualidade da energia elétrica | |
| dc.subject.keyword | Sobretensão | |
| dc.subject.keyword | Commissioning | |
| dc.subject.keyword | Distributed generation | |
| dc.subject.keyword | Photovoltaic microgeneration | |
| dc.subject.keyword | Power quality | |
| dc.subject.keyword | Overvoltage | |
| dc.title | Eficiência e limitações de sistemas de microgeração fotovoltaica: estudo de caso no Rio Grande do Norte e comparativo regional | |
| dc.title.alternative | Efficiency and limitations of photovoltaic microgeneration systems: a case study in Rio Grande do Norte and a regional comparative analysis | |
| dc.type | info:eu-repo/semantics/bachelorThesis |