🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Eficiência e limitações de sistemas de microgeração fotovoltaica: estudo de caso no Rio Grande do Norte e comparativo regional

dc.contributor.advisorCoelho, Rodrigo de Almeida
dc.contributor.advisormailrodrigo.coelho@ufersa.edu.br
dc.contributor.authorOliveira, Marcelo Targino de
dc.contributor.coadvisorLima, Érica Mangueira
dc.contributor.referee1Coelho, Rodrigo de Almeida
dc.contributor.referee2Lima, Érica Mangueira
dc.contributor.referee3Oliveira, Adriano Costa de
dc.contributor.referee4Freitas, Antônio Alisson Alencar
dc.coverage.spatialCaraúbas
dc.date.accessioned2026-02-03T12:01:41Z
dc.date.available2026-02-03T12:01:41Z
dc.date.issued2025-12-19
dc.description.abstractA expansão da microgeração fotovoltaica no Brasil, impulsionada pelo marco regulatório da geração distribuída, tem enfrentado desafios técnicos que comprometem o desempenho operacional de sistemas conectados à rede elétrica. Este trabalho teve como objetivo realizar um estudo de caso sobre as variações de tensão provenientes de um sistema de microgeração instalado no interior do Rio Grande do Norte, identificando os principais fatores que influenciam essas variações, analisando dados operacionais em diferentes condições e avaliando o impacto na qualidade da energia fornecida. O sistema analisado apresentou desligamentos recorrentes causados por sobretensão desde sua energização, comprometendo tanto a geração de energia quanto a continuidade operacional dos equipamentos conectados à instalação. A metodologia adotou abordagem de natureza aplicada com enfoque exploratório e descritivo, combinando medições em campo, monitoramento remoto via plataforma do fabricante e comparação com outras usinas de capacidade similar na região Nordeste. Foram realizadas inspeções termográficas, medições sistemáticas de tensão em diferentes pontos da instalação e avaliação de curvas de geração ao longo do período de comissionamento. A investigação revelou que a causa raiz dos problemas residia na combinação entre características inadequadas da rede de distribuição local e a configuração da infraestrutura de conexão, especificamente relacionada à distância significativa entre o inversor e o padrão de entrada. Foram implementadas múltiplas intervenções técnicas incluindo ajustes paramétricos no inversor, ativação de funções de proteção contra sobretensão, modificação da derivação do transformador de distribuição, substituição dos cabos de interligação por condutores de maior seção e adequação da string box. O estudo demonstrou que soluções isoladas foram insuficientes para resolver o problema, sendo necessária abordagem sistêmica para alcançar estabilidade operacional. O comparativo com outras instalações mostrou que a usina estudada apresentou os maiores níveis de sobretensão entre todas as unidades avaliadas, confirmando que a extensão do circuito alimentador constitui fator crítico no desempenho. Os resultados indicaram que o funcionamento adequado não depende exclusivamente da capacidade instalada, mas é fortemente influenciado pela infraestrutura de conexão e pelos níveis de tensão fornecidos pela concessionária.
dc.description.abstract2The expansion of photovoltaic microgeneration in Brazil, driven by the regulatory framework for distributed generation, has faced technical challenges that compromise the operational performance of systems connected to the electrical grid. This study aimed to conduct a case study on voltage variations originating from a microgeneration system installed in the interior of Rio Grande do Norte, identifying the main factors influencing these variations, analyzing operational data under different conditions, and evaluating the impact on the quality of supplied energy. The analyzed system exhibited recurrent shutdowns caused by overvoltage since commissioning, compromising both energy generation and the continuous operation of the connected equipment. The methodology adopted an applied approach with exploratory and descriptive focus, combining field measurements, remote monitoring via the manufacturer's platform, and comparison with other plants of similar capacity in the Northeast region. Thermographic inspections, systematic voltage measurements at different points in the installation, and evaluation of generation curves throughout the commissioning period were performed. The investigation revealed that the root cause of the problems lay in the combination of inadequate characteristics of the local distribution network and the connection infrastructure configuration, specifically related to the significant distance between the inverter and the connection point. Multiple technical interventions were implemented, including inverter parameter adjustments, activation of overvoltage protection functions, modification of the distribution transformer tap, replacement of interconnection cables with conductors of larger cross-section, and adaptation of the string box. The study demonstrated that isolated solutions were insufficient to solve the problem, requiring a systemic approach to achieve operational stability. Comparison with other installations showed that the studied plant experienced the highest overvoltage levels among all evaluated units, confirming that the length of the feeder circuit is a critical factor in performance. The results indicated that proper operation does not depend exclusively on installed capacity but is strongly influenced by the connection infrastructure and the voltage levels supplied by the utility.
dc.description.physical76 f.
dc.format.mimetypepdf
dc.identifier.advisorLatteshttp://lattes.cnpq.br/1211516714990564
dc.identifier.authorLatteshttps://lattes.cnpq.br/9742438256863834
dc.identifier.bibliographicCitationOLIVEIRA, Marcelo Targino de. Eficiência e limitações de sistemas de microgeração fotovoltaica: estudo de caso no Rio Grande do Norte e comparativo regional. 2025. 76 f. TCC (Graduação) - Bacharelado em Engenharia Elétrica, Universidade Federal Rural do Semi-Árido, Caraúbas, 2025.
dc.identifier.coadvisorLatteshttp://lattes.cnpq.br/0530843719588041
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/15006
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Caraúbas - CMC
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Engenharias - DE
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA ELETRICA
dc.subject.keywordComissionamento
dc.subject.keywordGeração distribuída
dc.subject.keywordMicrogeração fotovoltaica
dc.subject.keywordQualidade da energia elétrica
dc.subject.keywordSobretensão
dc.subject.keywordCommissioning
dc.subject.keywordDistributed generation
dc.subject.keywordPhotovoltaic microgeneration
dc.subject.keywordPower quality
dc.subject.keywordOvervoltage
dc.titleEficiência e limitações de sistemas de microgeração fotovoltaica: estudo de caso no Rio Grande do Norte e comparativo regional
dc.title.alternativeEfficiency and limitations of photovoltaic microgeneration systems: a case study in Rio Grande do Norte and a regional comparative analysis
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
MarceloTO_MONO.pdf
Tamanho:
3,66 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: