Análise do atendimento normativo em sistemas de drenagem de ar-condicionado em obras de pequeno porte
| dc.contributor.advisor | Lima, Daniela de Freitas | |
| dc.contributor.advisormail | daniela.freitas@ufersa.edu.br | |
| dc.contributor.author | Lima, Francisco Diego Nogueira | |
| dc.contributor.referee1 | Lima, Daniela de Freitas | |
| dc.contributor.referee2 | Nunes, José Ronaldo Souza | |
| dc.contributor.referee3 | Tsuyuguchi, Bárbara Barbosa | |
| dc.coverage.spatial | Pau dos Ferros | |
| dc.date.accessioned | 2026-07-17T12:34:24Z | |
| dc.date.available | 2026-07-17T12:34:24Z | |
| dc.date.issued | 2026-07-03 | |
| dc.description.abstract | O sistema de dreno do ar-condicionado é uma diretriz de extrema importância para garantir a salubridade, evitar infiltrações e assegurar a eficiência térmica das edificações, com isso apresenta-se a relevância de que sejam seguidas as normas brasileiras quando da instalação desse sistema. O atendimento às normas exige um projeto hidrossanitário bem estruturado que impede o descarte irregular e previne a contaminação do ar interior. Este trabalho tem como objetivo analisar a execução de instalações hidrossanitárias associadas a sistemas de ar-condicionado em obras de pequeno porte, com foco no atendimento às normas técnicas brasileiras. Para tanto, realizou-se a análise normativa, em específico a NBR 16655-1:2018. Na sequência, foram feitas visitas de campo com os devidos registros fotográficos realizados em duas obras de pequeno porte localizadas no município de Apodi-RN e em quatro obras de pequeno porte localizadas no município de Potiretama-CE. Foi verificado que nestas obras não há o atendimento das exigências da norma quanto às instalações de ares-condicionados. Os resultados obtidos pela visualização das imagens e a comparação com o que preconizam as normas brasileiras evidenciam uma elevada incidência de falhas construtivas, entre elas: a ausência de sifão e o destino final da água condensada, inclinação inadequada das tubulações e utilização de materiais impróprios. Também foram observadas situações capazes de favorecer a formação de lodo. Além disso, verificou-se o frequente descumprimento da norma técnica NBR 16655-1:2018, o que compromete o desempenho dos sistemas de climatização e favorece o surgimento de infiltrações, danos construtivos e riscos à saúde dos usuários, devido à possível proliferação de microrganismos em ambientes com umidade excessiva. Conclui-se que a ausência de padronização dos processos executivos, aliada à deficiência na qualificação da mão de obra e à falta de fiscalização técnica, contribui significativamente para a ocorrência de falhas nas instalações de ares-condicionados em obras de pequeno porte nos municípios estudados. Isto, de modo geral, impacta negativamente a durabilidade das edificações, a eficiência dos sistemas e a qualidade do ambiente interno. | |
| dc.description.abstract2 | The air conditioning drainage system is a critically important aspect to ensure hygiene, prevent leaks, and guarantee the thermal efficiency of buildings. This highlights the importance of adhering to Brazilian standards when installing this system. Compliance with standards requires a well-structured hydrosanitary project which prevents improper disposal and indoor air contamination. This study aims to analyze the execution of plumbing and sanitary installations associated with air-conditioning systems in small-scale projects, focusing on compliance with Brazilian technical standards. To this end, a normative analysis was carried out, specifically NBR 16655-1:2018. Subsequently, field visits were conducted -with the corresponding photographic documentation - at two small-scale construction sites located in the municipality of Apodi, Rio Grande do Norte and on four small-scale projects located in the municipality of Potiretama, Ceará. It was found that these works do not comply with the standard's requirements regarding air conditioning installations. The results obtained from the visualization of the images and the comparison with the provisions of Brazilian standards. The results show a high incidence of construction defects, and, among them: the absence of a trap, improper pipe slope, and the use of unsuitable materials. Furthermore, frequent non-compliance with technical standards, such as NBR 16655-1:2018, was observed. This compromises the performance of the HVAC systems, it favors the emergence of leaks, structural damage, and risks to the health of users due to the possible proliferation of microorganisms in environments with excessive humidity. It is concluded that the lack of standardization of executive processes, coupled with deficiencies in workforce qualifications and a lack of technical oversight, contributes significantly to the occurrence of failures in air conditioning systems. Generally speaking, this negatively impacts the durability of buildings, the efficiency of systems, and the quality of the indoor environment. | |
| dc.description.physical | 49 f. | |
| dc.format.mimetype | ||
| dc.identifier.authorLattes | http://lattes.cnpq.br/0867633921873063 | |
| dc.identifier.bibliographicCitation | LIMA, Francisco Diego Nogueira. Análise do atendimento normativo em sistemas de drenagem de ar-condicionado em obras de pequeno porte. 49 f. 2026. Monografia (Bacharelado Interdicisplinar em Ciências e Tecnologia) - Centro Multidisciplinar de Pau dos Ferros, Universadade Federal Rural do Semiárido,Pau dos Ferros,2026 | |
| dc.identifier.uri | https://repositorio.ufersa.edu.br/handle/prefix/15420 | |
| dc.language.iso | pt_BR | |
| dc.publisher.center | Centro Multidisciplinar de Pau dos Ferros - CMPF | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | Departamento de Ciências Exatas e Naturais - DECEN | |
| dc.publisher.initials | UFERSA | |
| dc.publisher.institution | Universidade Federal Rural do Semi-Árido | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.holder | UFERSA | |
| dc.rights.license | Attribution-ShareAlike 3.0 Brazil | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/3.0/br/ | |
| dc.subject.cnpq | CIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA | |
| dc.subject.keyword | Climatização | |
| dc.subject.keyword | Drenagem do condensado | |
| dc.subject.keyword | Patologias | |
| dc.subject.keyword | Normas técnicas. | |
| dc.title | Análise do atendimento normativo em sistemas de drenagem de ar-condicionado em obras de pequeno porte | |
| dc.title.alternative | Analysis of compliance with standards for air conditioning drainage systems in small-scale construction projects | |
| dc.type | info:eu-repo/semantics/bachelorThesis |