🚨 Informamos aos concluintes que após a validação do orientador no sistema, A BIBLIOTECA PRECISA DE 7 DIAS ÚTEIS para tratar e processar os dados. Por isso, NÃO DEIXE PARA ENVIAR O TCC (graduação ou pós-graduação) DE ÚLTIMA HORA. Dúvidas: repositorio@ufersa.edu.br🚨

Controle de potência de aerogeradores de indução duplamente alimentados (DFIG) em um sistema de potência radial utilizando Particle Swarm Optimization (PSO) e Ladder Iterative Technique (LIT)

dc.contributor.advisorMoura, Adriano Aron Freitas de
dc.contributor.advisormailrepositorio@ufersa.edu.br
dc.contributor.authorOliveira, Sanderson Aron Moura Gurgel Sinedino de
dc.contributor.coadvisorRocha, Ednardo Pereira da
dc.contributor.referee1Moura, Adriano Aron Freitas de
dc.contributor.referee2Silva, Juliano Costa Leal da
dc.coverage.spatialMossoró
dc.date.accessioned2025-07-17T17:56:54Z
dc.date.available2025-07-17T17:56:54Z
dc.date.issued2024-04-30
dc.description.abstractA análise de fluxo de carga é um procedimento essencial no controle do sistema elétrico de potência, pois ajuda a calcular as tensões em cada barra e as correntes em cada ramo. Esse mecanismo é utilizado direta ou indiretamente em várias aplicações do sistema elétrico de potência, como geração distribuída, localização banco de capacitores, melhorias na qualidade de energia, otimização do sistema elétrico, entre outros. Este trabalho propõe determinar os valores das tensões do rotor para controlar as potências no estator das máquinas eólicas no valor determinado em uma rede de transmissão com duas linhas de transmissão e uma rede de 22kV. Para isso foi simulado um sistema de geração eólica baseado em DFIG (do inglês, Doubly-fed Induction Generator) em funcionamento, assim como sua operacionalização e controle. Foi utilizada a Otimização por Nuvem de Partículas (do inglês, Particle Swarm Optimization - PSO), para se obter uma determinada potência ativa e reativa trifásicas no estator usando a Ladder Iterative Technique (LIT), algoritmo de fluxo de carga em Matlab para determinar a tensão do rotor. A modelagem do DFIG foi desenvolvida através de modelos que refletem os mesmos cálculos realizados pelo software ATP-EMTP em regime permanente, conhecendo o comportamento das grandezas elétricas em vários pontos da topologia DFIG e posteriormente comparados os resultados obtidos no Matlab com os modelos desenvolvidos nas simulações. A PSO foi utilizada para determinar as tensões no rotor que serão capazes de entregar potências determinadas no estator. Os resultados apresentados mostraram que para valores altos de potência no estator no modo supersíncrono, o erro é menor, tornando os valores teóricos mais próximos dos valores simulados no ATP. Já no modo subsíncrono, o algoritmo PSO apresentou um melhor desempenho para valores de VS (tensão no estator) até 20MW chegando a zerar o custo a função objetivo da PSO, porém na simulação com VS de 30MVA apresentou um custo elevado, não convergendo nas iterações e apresentou um erro de 20,3% comparando o valor teórico aplicado no Matlab com o obtido no ATP para potência no estator. Após simulações, constatou-se que a PSO representa uma técnica de otimização rápida e robusta, capaz de resolver uma variedade de problemas complexos, incluindo aqueles de natureza não-linear, não diferenciável e até mesmo multi-objetivo. Além disso, suas vantagens principais incluem sua facilidade de implementação computacional, exigindo apenas poucos parâmetros e demonstrando rápida convergência. No entanto, é preciso considerar suas desvantagens, como a baixa convergência em espaços de alta dimensão e uma notável sensibilidade aos parâmetros de execução.
dc.description.abstract2Load flow analysis is an essential procedure in power system control, as it helps to calculate the voltages at each bus and the currents in each branch. This mechanism is used directly or indirectly in various power system applications, such as distributed generation, capacitor bank location, power quality improvements, power system optimization, and others. This work proposes to determine the rotor voltage values to control the stator power of wind turbine machines at the specified value in a transmission network with two transmission lines and a 22kV network. For this purpose, a wind generation system based on DFIG (Doubly-fed Induction Generator) was simulated, as well as its operation and control. Particle Swarm Optimization (PSO) was used to obtain a specific three-phase active and reactive power in the stator using the Ladder Iterative Technique (LIT), a load flow algorithm in Matlab to determine the rotor voltage. The DFIG modeling was developed through models that reflect the same calculations performed by the ATP-EMTP software in steady state, knowing the behavior of the electrical quantities at various points of the DFIG topology and subsequently comparing the results obtained in Matlab with the models developed in the simulations. PSO was used to determine the rotor voltages that will be able to deliver specified power in the stator. The results showed that for high stator power values in the supersynchronous mode, the error is smaller, making the theoretical values closer to the values simulated in ATP. In the subsynchronous mode, the PSO algorithm showed better performance for VS (stator voltage) values up to 20MW, reaching zero cost to the PSO objective function, but in the 30MVA VS simulation, it showed high cost, not converging in the iterations, and showed an error of 20.3% when comparing the theoretical value applied in Matlab with the one obtained in ATP for stator power. After simulations, it was found that PSO represents a fast and robust optimization technique, capable of solving a variety of complex problems, including those of a non-linear, non-differentiable, and even multi-objective nature. Furthermore, its main advantages include ease of computational implementation, requiring only a few parameters, and demonstrating rapid convergence. However, its disadvantages, such as low convergence in high-dimensional spaces and notable sensitivity to execution parameters, must be considered.
dc.description.physical85 f. : Il.
dc.format.mimetypepdf
dc.identifier.advisorLatteshttp://lattes.cnpq.br/7699437598190399
dc.identifier.authorLatteshttp://lattes.cnpq.br/1469563913854321
dc.identifier.bibliographicCitationOLIVEIRA, Sanderson Aron Moura Gurgel Sinedino de. Controle de potência de aerogeradores de indução duplamente alimentados (DFIG) em um sistema de potência radial utilizando Particle Swarm Optimization (PSO) e Ladder Iterative Technique (LIT). 2024. 85 f. Dissertação (Mestrado) - Curso de Mestrado em Engenharia Elétrica, Universidade Federal Rural do Semi-Árido, Mossoró, 2024. Disponível em: https://repositorio.ufersa.edu.br. Acesso em: 25 jun. 2025.
dc.identifier.coadvisorLatteshttp://lattes.cnpq.br/8754856801344344
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/13549
dc.language.isopt_BR
dc.publisher.centerCentro de Engenharias - CE
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétrica
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA ELETRICA
dc.subject.keywordGerador de indução duplamente alimentado
dc.subject.keywordRotor eólico
dc.subject.keywordOtimização por nuvem de partículas
dc.subject.keywordLinhas de transmissão
dc.subject.keywordDoubly Fed Induction Generator
dc.subject.keywordWind Rotor
dc.subject.keywordTransmission lines
dc.subject.keywordParticle swarm optimization
dc.titleControle de potência de aerogeradores de indução duplamente alimentados (DFIG) em um sistema de potência radial utilizando Particle Swarm Optimization (PSO) e Ladder Iterative Technique (LIT)
dc.title.alternativePower control of doubly fed induction wind generators (DFIG) in a radial power system using Particle Swarm Optimization (PSO) and Ladder Iterative Technique (LIT)
dc.typeinfo:eu-repo/semantics/masterThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
SandersonAMGSO_Dissertação
Tamanho:
3,18 MB
Formato:
Unknown data format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: