Avaliação do dimensionamento dos ar-condicionados do bloco de salas I da UFERSA Campus Caraúbas

dc.contributor.advisorSilva, Gleryston Thiago Gomes da
dc.contributor.authorMedeiros, Sharmilla de Almeida
dc.contributor.referee1Silva, Gleryston Thiago Gomes da
dc.contributor.referee2Bezerra, Italla Medeiros
dc.contributor.referee3Espindola, Rafael Luz
dc.coverage.spatialCaraúbas
dc.date.accessioned2024-08-20T22:45:48Z
dc.date.available2024-08-20T22:45:48Z
dc.date.issued2016-11-10
dc.description.abstractOs estudos do conforto térmico deseja analisar e estabelecer as condições necessárias para garantir um ambiente térmico, que detenha de condições humanas satisfatória para o bem-estar. Nessa busca deve se fazer algumas considerações prévias, sejam elas durante toda a construção do recinto, desde momento do desenvolvimento do projeto, levantamento e até a realização da edificação. Sendo assim, existem variáveis que influenciam de forma direta e indireta, para adquirir um ambiente agradável. Havendo necessidade do uso de um equipamento que proporcione esse bem-estar, como os ar-condicionados. A UFERSA, localizada no município de Caraúbas-RN, apresenta temperaturas elevadas, alta umidade entre outros fatores que resultam em sensações de desconforto. Foram analisadas as variáveis climáticas, pessoais e as do ambiente. A proposta deste trabalho consiste em avaliar o projeto do dimensionamento dos ar-condicionados do Bloco de Sala I, foi feita uma avaliação nas condições e desempenhos equipamentos, analisando sua estrutura física e também seu desempenho. As avaliações foram feitas na instituição, entre o mês de setembro e outubro de 2016, considerando algumas variáveis como, carga de condução, radiação solar, aspectos da edificação, calor proveniente da iluminação, calor sensível e o calor latente proveniente dos usuários. Com essas variáveis foi calculada a carga térmica total de maneira simplificada. Com o cálculo da carga térmica foi feita uma comparação com os aparelhos utilizados em salas, verificando que os modelos utilizados em sala poderiam ser substituídos por outro de consumo mais baixo resultando assim é uma demanda menor de energia elétrica. E para o funcionamento desses aparelhos continuem de forma eficaz é preciso uma manutenção periódica.
dc.description.abstract2The thermal comfort studies wish to analyze and establish the necessary conditions to ensure a thermal environment, which holds human conditions satisfactory to well-being. In this search one must make some previous considerations, be they during all the construction of the enclosure, from the moment of the development of the project, survey and until the construction of the building. Thus, there are variables that influence directly and indirectly, to acquire a pleasant environment. If there is need for the use of equipment that provides this well-being, such as air-conditioned. UFERSA, located in the city of Caraúbas-RN, presents high temperatures, high humidity and other factors that result in feelings of discomfort. Climatic, personal and environmental variables were analyzed. The purpose of this work is to evaluate the design of the air conditioners in Block I, an evaluation was made on the conditions and performance of the equipment, analyzing their physical structure and their performance. The evaluations were made at the institution between September and October 2016, considering some variables such as driving load, solar radiation, building aspects, heat coming from the lighting, sensible heat and the latent heat coming from the users. With these variables, the total thermal load was calculated in a simplified way. With the calculation of the thermal load a comparison was made with the apparatuses used in rooms, verifying that the models used in the room could be replaced by another one of lower consumption resulting in this is a lower demand of electric energy. And for the operation of these devices to continue effectively, periodic maintenance is required.
dc.description.physical54 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationMEDEIROS, Sharmilla de Almeida. Avaliação do dimensionamento dos ar-condicionados do bloco de salas I da Ufersa Campus Caraúbas. 2016. 54 f. TCC (Graduação) - Curso de Bacharelado em Ciência e Tecnologia, Universidade Federal Rural do Semi-Árido, Caraúbas, 2016.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/11417
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Caraúbas - CMC
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.rights.holderUFERSA
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA
dc.subject.keywordConforto térmico
dc.subject.keywordCarga térmica
dc.subject.keywordAr – condicionados
dc.titleAvaliação do dimensionamento dos ar-condicionados do bloco de salas I da UFERSA Campus Caraúbas
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
SharmillaAM_MONO.pdf
Tamanho:
4,25 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: