Dimensionamento e uso de interruptores diferenciais residuais em residências da cidade de Coronel João Pessoa/RN

dc.contributor.advisorCunha, Sharon Dantas da
dc.contributor.authorSilva, Júlio Cesar de Souza
dc.contributor.referee1Cunha, Sharon Dantas da
dc.contributor.referee2Lima, Adelson Menezes
dc.contributor.referee3Figueiredo, Kytéria Sabina Lopes de
dc.coverage.spatialPau dos Ferros
dc.date.accessioned2024-10-14T17:44:04Z
dc.date.available2024-10-14T17:44:04Z
dc.date.issued2021-05-24
dc.description.abstractA utilização de aparelhos de proteção em instalações elétricas residenciais é um fator indispensável para o funcionamento correto dos circuitos elétricos. A NBR 5410 prevê a obrigatoriedade de alguns aparelhos para proteção de sobrecarga, como disjuntor ou fusível, e corrente de fuga, Interruptor Diferencial Residual (IDR). Nesse contexto, a utilização do IDR é importante para proteger os circuitos elétricos contra a presença de fugas de corrente na instalação, seccionando o seu funcionamento, sempre quando a corrente ultrapassa um limite de segurança preestabelecido. Desta forma, o IDR protege os indivíduos e demais animais domésticos contra choques elétricos que podem ser originados através do contato involuntário com partes energizadas dos circuitos. Entretanto, apesar da obrigatoriedade da implementação desses aparelhos, a sua instalação ainda é bastante negligenciada. Partindo deste pressuposto, este trabalho tem por objetivo analisar o IDR, seu princípio de funcionamento e dimensionamento em instalações residenciais. Além disso, foram realizadas duas pesquisas: a primeira sobre a presença dos IDR nas residências com menos de dez anos de construção na cidade de Coronel João Pessoa – RN, e a segunda com os eletricistas que trabalham na região desta cidade. Os resultados da pesquisa mostraram 57,5% das residências com um único disjuntor, e a completa ausência do IDR nas mesmas, além de 95,7% da população local apresentarem um completo desconhecimento em relação a utilização e funcionalidades de tais aparelhos, associado ao fato de que cerca 83,3% dos eletricistas questionados, não utilizam projetos elétricos para a execução de suas instalações, e apenas 66,7% admitem a utilização de IDR.
dc.description.abstract2The use of protective devices in residential electrical installations is an indispensable factor for the correct functioning of electrical circuits. NBR 5410 presages the mandatory nature of some devices for overload protection, such as circuit breaker or fuse, and leakage current, Residual Differential Switch (RDS). In this context, the use of RDS is important to protect electrical circuits against the presence of current leakage in the installation, cutting off their operation, whenever the current exceeds a pre-established safety limit. In this way, the RDS protects individuals and other pets against electrical shocks that can originate through involuntary contact with energized parts of the circuits. However, despite the mandatory implementation of these devices, their installation is still quite neglected. Based on this assumption, this work aims to analyze the RDS, its operating principle and dimensioning in residential installations. In addition, two surveys were carried out: the first on the presence of RDSs in homes with less than ten years of construction in the city of Coronel João Pessoa – RN, and the second on electricians working in the region of this city. The survey results showed 57.5% of households with a single circuit breaker, and the complete absence of the RDS in them, in addition to 95.7% of the local population showing a complete lack of knowledge regarding the use and functionality of such devices, associated to the fact that around 83.3% of the electricians questioned do not use electrical projects for the execution of their installations, and only 66.7% admit the use of RDS.
dc.description.physical60 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationSILVA, Júlio Cesar de Souza. Dimensionamento e uso de interruptores diferenciais residuais em residências da cidade de Coronel João Pessoa/RN. 2021. 60 f. Monografia (Graduação em Ciência e Tecnologia), Centro Multidisciplinar de Pau dos Ferros, Universidade Federal Rural do Semi-Árido, Pau dos Ferros, 2021.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/11730
dc.language.isopt_BR
dc.publisher.centerCentro Multidisciplinar de Pau dos Ferros - CMPF
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.rights.holderUFERSA
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::CIENCIA E TECNOLOGIA
dc.subject.keywordDispositivo elétrico
dc.subject.keywordNBR 5410
dc.subject.keywordChoques Elétricos
dc.titleDimensionamento e uso de interruptores diferenciais residuais em residências da cidade de Coronel João Pessoa/RN
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
JúlioCSS_MONO.pdf
Tamanho:
2,01 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: