Desenvolvimento de um sistema de tratamento de água para fábrica de tintas: uma abordagem convencional e sustentável

dc.contributor.advisorNóbrega, Geraldine Angélica Silva da
dc.contributor.advisormailgeraldinenobrega@ufersa.edu.br
dc.contributor.authorAndrade Neto, Francisco Medeiros
dc.contributor.referee1Nóbrega, Geraldine Angélica SIlva da
dc.contributor.referee2Barbosa, Fernanda Larissa do Vale
dc.contributor.referee3Thaís do Carmo Oliveira Silva
dc.coverage.spatialMossoró
dc.date.accessioned2025-07-18T13:02:13Z
dc.date.available2025-07-18T13:02:13Z
dc.date.issued2025-03-26
dc.description.abstractA indústria de tintas gera efluentes com características complexas devido à presença de resíduos químicos, como pigmentos, resinas, espessantes, dispersantes, bactericidas, fungicidas e coalescentes. Esses componentes podem causar impactos ambientais significativos se descartados de forma inadequada. A fim de compor as atividades realizadas no estágio obrigatório, foi desenvolvido um sistema de tratamento de água residual para uma fábrica de tintas de pequeno porte, localizada na região do semiárido do estado do Rio Grande do Norte. A pesquisa comparou uma abordagem convencional, utilizando sulfato de alumínio como agente coagulante, e uma abordagem sustentável, empregando biopolímeros. No método convencional, o sulfato de alumínio foi utilizado para remover partículas em suspensão e matéria orgânica, seguido de processos de decantação e filtração. No método sustentável, os biopolímeros foram aplicados no processo de complexação para reduzir a carga química do efluente. Os sistemas de tratamento desenvolvidos foram avaliados por meio de parâmetros como turbidez, pH, condutividade elétrica, dureza e razão de adsorção de sódio (RAS), com o objetivo de viabilizar a reutilização da água para irrigação. Os resultados indicaram que o método convencional apresentou maior eficiência na remoção de contaminantes, reduzindo significativamente a dureza e os níveis de cátions e ânions. Embora o tratamento sustentável tenha promovido uma melhoria na qualidade da água, sua eficiência foi inferior à do método convencional. O sistema de tratamento baseado no método convencional foi o mais adequado para o efluente da indústria de tintas avaliada, garantindo que a água tratada atendesse aos padrões estabelecidos pelo CONAMA para reutilização na irrigação.
dc.description.abstract2The paint industry generates effluents with complex characteristics due to the presence of chemical residues such as pigments, resins, thickeners, dispersants, bactericides, fungicides, and coalescents. These components can cause significant environmental impacts if improperly disposed of. This study developed a wastewater treatment system for a small paint factory located in the semi-arid region of the state of Rio Grande do Norte, Brazil. The research compared a conventional approach, using aluminum sulfate as a coagulant agent, and a sustainable approach, employing biopolymers. In the conventional method, aluminum sulfate was used to remove suspended particles and organic matter, followed by sedimentation and filtration processes. In the sustainable method, biopolymers were applied in the complexation process to reduce the effluent's chemical load. The developed treatment systems were evaluated based on parameters such as turbidity, pH, electrical conductivity, hardness, and sodium adsorption ratio (SAR), aiming to enable the reuse of the treated water for irrigation. The results indicated that the conventional method demonstrated greater efficiency in contaminant removal, significantly reducing hardness and cation and anion levels. Although the sustainable treatment improved water quality, its efficiency was lower than that of the conventional method. The treatment system based on the conventional method proved to be the most suitable for the evaluated paint industry effluent, ensuring that the treated water met the standards established by CONAMA for reuse in irrigation.
dc.description.physical35 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationANDRADE Neto, Francisco Medeiros. Desenvolvimento de um sistema de tratamento de água para fábrica de tintas: uma abordagem convencional e sustentável. 2025. (Bacharelado em Engenharia Química) - Universidade Federal Rural do Semi-Árido, Mossoró 2025.
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/13564
dc.language.isopt_BR
dc.publisher.centerCentro de Engenharias - CE
dc.publisher.countryBrasil
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.holderUFERSA
dc.rights.licenseAttribution-ShareAlike 3.0 Brazilen
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA QUIMICA
dc.subject.keywordTratamento de efluentes
dc.subject.keywordIndústria de tintas
dc.subject.keywordBiopolímeros
dc.subject.keywordSustentabilidade
dc.subject.keywordEffluent treatment
dc.subject.keywordPaint industry
dc.subject.keywordBiopolymers
dc.subject.keywordSustainability
dc.titleDesenvolvimento de um sistema de tratamento de água para fábrica de tintas: uma abordagem convencional e sustentável
dc.title.alternativeDevelopment of a water treatment system for a paint factory: a conventional and sustainable approach
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
AndradeNetoFM_Mono.pdf
Tamanho:
921,22 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: