Please use this identifier to cite or link to this item: http://repositorio.ufersa.edu.br/handle/prefix/5057
metadata.dc.type: Trabalho de Conclusão de Curso
Title: Manifestações patológicas em estrutura metálica: um estudo de caso da corrosão, causas e consequências em pilares treliçados na cidade de Água Nova-RN
metadata.dc.creator: Bessa, Antônio Ronivon de Oliveira
metadata.dc.contributor.advisor1: Silva, Matheus Fernandes de Araújo
metadata.dc.contributor.referee1: Queiroz, José Henrique Maciel de
metadata.dc.contributor.referee2: Rocha, Fabíola Luana Maia
metadata.dc.description.resumo: As estruturas metálicas requerem cuidados nas fases de projeto e execução que ainda não são tão difundidos no meio da construção civil, fazendo com que esse sistema estrutural, de modo geral, não seja tão utilizado quando em comparação com os demais sistemas. Umas das características do aço que mais merece atenção é a tendência natural ao desenvolvimento da corrosão, sendo esse processo o principal causador de manifestações patológicas nesse sistema. Nesse contexto, no seguinte trabalho realizou-se um estudo de caso das patologias em pilares treliçados de uma estrutura localizada na cidade de Água Nova-RN. Utilizou-se como metodologia a visualização em campo da estrutura com registros fotográficos, e revisão bibliográfica com o objetivo de identificar as causas, consequências e soluções para as anomalias encontradas na inspeção. Verificou-se nos pilares treliçados da edificação a ocorrência de corrosão uniforme, por frestas e ranhuras como geradora da degradação da estrutura, onde foram ocasionadas por erros de projeto e execução, falta de manutenção e inspeção preventiva. Para solucionar tais problemas sugeriu-se a execução das ligações de base conforme recomendações normativas e um sistema de pintura adequado, bem como a manutenção preventiva da edificação.
Abstract: Metal structures require care in the design and execution phases that are not yet so widespread in the middle of construction, making this structural system, in general, not as used when compared to other systems. One of the characteristics of steel that deserves the most attention is the natural tendency of corrosion to develop, and this process is the main cause of pathological manifestations in this system. In this context, the following work was carried out a case study of the pathologies in lattice pillars of a structure located in the city of Água NovaRN. It was used as methodology the field visualization of the structure with photographic records, and bibliographic review in order to identify the causes, consequences and solutions for the anomalies found in the inspection. It was verified in the truss pillars of the building the occurrence of uniform corrosion, through cracks and grooves as a generator of structure degradation, where they were caused by design and execution errors, lack of maintenance and preventive inspection. To solve such problems, it was suggested to perform the basic connections according to normative recommendations and a suitable painting system, as well as the preventive maintenance of the building.
Keywords: Patologia do aço
Estruturas de Aço
Manutenção
Pathology of steel
Steel structures
Maintenance
metadata.dc.subject.cnpq: CNPQ::ENGENHARIAS
metadata.dc.language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal Rural do Semi-Árido
metadata.dc.publisher.initials: UFERSA
metadata.dc.publisher.department: Centro Multidisciplinar de Pau dos Ferros
Citation: Bessa (2019) (BESSA, 2019)
metadata.dc.rights: Acesso Aberto
URI: http://repositorio.ufersa.edu.br/handle/prefix/5057
Issue Date: 14-Aug-2019
Appears in Collections:Engenharia Civil

Files in This Item:
File Description SizeFormat 
AntônioROB_MONO.pdf5.89 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.