Avaliação das medidas de segurança contra incêndio: estudo de caso no pavimento ambulatorial de um hospital materno-infantil localizado no Estado do Rio Grande do Norte

dc.contributor.advisorOliveira, Fabrícia Nascimento de
dc.contributor.authorSilva, Maria Clara Dantas da
dc.contributor.referee1Oliveira, Fabrícia Nascimento de
dc.contributor.referee2Medeiros, Alisson Gadelha de
dc.contributor.referee3Andrade Filho, Jerônimo
dc.coverage.spatialMossoró
dc.date.accessioned2023-11-23T20:28:13Z
dc.date.available2023-11-23T20:28:13Z
dc.date.issued2023-05-19
dc.description.abstractOs hospitais são edificações complexas que possuem diversos setores interligados e interdependentes, além disso, a população existente possui características muito específicas que requer que todo o sistema de segurança contra incêndio seja projetado de maneira que atenda integralmente a essas peculiaridades. Logo, o objetivo desse trabalho é aferir os sistemas de prevenção e combate a incêndio de um prédio público hospitalar no Estado do Rio Grande do Norte de acordo com as exigências das normas e instruções técnicas do Corpo de Bombeiros Militar do Rio Grande do Norte e, concomitantemente, avaliar a conformidade quanto aos parâmetros e requisitos mínimos de segurança contra incêndio. Para atingir os objetivos do trabalho, a edificação hospitalar foi classificada de acordo com a Instrução Técnica de nº 01/2022 do CBM/RN sendo grupo/divisão H-3, área ocupada de 13.609,80 m², altura de 18,00m e risco baixo. Com isso, as medidas avaliadas por meio de checklists estruturados foram: acesso de viatura na edificação; segurança estrutural contra incêndio; compartimentação horizontal ou de áreas; compartimentação vertical; gerenciamento de risco de incêndio; saídas de emergência; brigada de incêndio; iluminação de emergência; detecção de incêndio e alarme de incêndio; sinalização de emergência; extintores; hidrantes e mangotinhos. Os resultados mostram que, de um total de 122 parâmetros analisados, 85,2% das medidas de segurança contra incêndio estavam em conformidade e 14,8% estavam em desconformidade. Observou-se que o sistema de chuveiros automáticos estava inoperante devido ao manômetro e pressostato marcarem zero, porém poderia ser operante, pois sua estrutura já estava implementada no hospital e se tornaria ser útil no combate aos princípios de incêndio. Apesar de ser um requisito alternativo legal, a compartimentação horizontal ou de áreas apresentou todos os seus itens em conformidade, mesmo quando a edificação possui o sistema de chuveiros automáticos. Foi observada a inexistência de gerenciamento de risco e negligência na sinalização de emergência, o que pode aumentar o risco de acidentes e lesões. Destaca-se a importância de verificar o cumprimento mínimo das exigências do Corpo de Bombeiros na edificação hospitalar como um todo e a necessidade de ação conjunta entre as medidas de prevenção para garantir a efetividade da segurança contra incêndios. Logo, este estudo fornece subsídio técnico para produção de futuros trabalhos e pesquisas no âmbito da prevenção e combate a incêndio e pânico de estabelecimentos assistenciais de saúde.
dc.description.abstract2Hospitals are complex buildings that have several interconnected and interdependent sectors, in addition, the existing population has very specific characteristics that require that the entire fire safety system be designed in a way that fully meets these peculiarities. Therefore, the objective of this work is to assess the fire prevention and fighting systems of a public hospital building in the State of Rio Grande do Norte according to the requirements of the standards and technical instructions of the Military Fire Department of Rio Grande do Norte and, concomitantly, to evaluate compliance with the parameters and minimum requirements of fire safety. To achieve the objectives of the study, the hospital building was classified according to Technical Instruction No. 01/2022 of the CBM/RN being group/division H-3, occupied area of 13,609.80 m², height of 18.00m and low risk. Thus, the measures evaluated through structured checklists were: vehicle access in the building; structural fire safety; horizontal or area compartmentalization; vertical compartmentalization; fire risk management; emergency exits; fire brigade; emergency lighting; fire detection and fire alarm; emergency signaling; extinguishers; hydrants and mangotinhos. The results show that, out of a total of 122 parameters analyzed, 85.2% of the fire safety measures were in compliance and 14.8% were in non-compliance. It was observed that the automatic shower system was inoperative due to the pressure gauge and pressure switch marking zero, but it could be operative, since its structure was already implemented in the hospital and would become useful in fighting the principles of fire. Despitebeing an alternative legal requirement, horizontal or area compartmentation has presented all its items in compliance, even when the building has the automatic shower system. The lack of risk management and negligence in emergency signaling was observed, which can increase the risk of accidents and injuries. Dit is important to verify the minimum compliance with the requirements of the Fire Department in the hospital building as a whole and the need for joint action between prevention measures to ensure the effectiveness of fire safety. Therefore, and this study provides technical support for the production of future work and research in the field of prevention and fighting of fire and panic of health care establishments.
dc.description.physical114 f.
dc.format.mimetypepdf
dc.identifier.bibliographicCitationSILVA, Maria Clara Dantas da. Avaliação das medidas de segurança contra incêndio: estudo de caso no pavimento ambulatorial de um hospital materno-infantil localizado no estado do rio grande do norte. 2023. 114 f. TCC (Graduação) - Curso de Engenharia Civil, Centro de Engenharias - CE, Universidade Federal Rural do Semi-Árido - UFERSA, Mossoró/RN, 2023. Citação com autor incluído no texto: Silva (2023) Citação com autor não incluído no texto: (SILVA, 2023)
dc.identifier.urihttps://repositorio.ufersa.edu.br/handle/prefix/9693
dc.language.isopt_BR
dc.publisher.centerCentro de Engenharias - CE
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Engenharia e Ciências Ambientais - DECAM
dc.publisher.initialsUFERSA
dc.publisher.institutionUniversidade Federal Rural do Semi-Árido
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.rights.holderUFERSA
dc.rights.urihttp://creativecommons.org/licenses/by-sa/3.0/br/
dc.subject.cnpqENGENHARIAS::ENGENHARIA CIVIL
dc.subject.keywordServiços de saúde
dc.subject.keywordCombate a incêndio
dc.subject.keywordRisco da edificação
dc.subject.keywordSegurança hospitalar
dc.titleAvaliação das medidas de segurança contra incêndio: estudo de caso no pavimento ambulatorial de um hospital materno-infantil localizado no Estado do Rio Grande do Norte
dc.typeinfo:eu-repo/semantics/bachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
MariaCDS_MONO.pdf
Tamanho:
2,3 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1,58 KB
Formato:
Item-specific license agreed upon to submission
Descrição: